Literature DB >> 11440038

The clinical value of 18F-FDG detection with a dual-head coincidence camera: a review.

I Ak1, J A Blokland, E K Pauwels, M P Stokkel.   

Abstract

Positron emission tomography (PET) has evolved into a technique that can accurately determine the distribution of positron-emitting radionuclides. The addition of a coincidence detection mode to a standard dual-head detector system has resulted in the option of single-photon and annihilation coincidence detection. This new device for imaging fluorine-18 2-fluoro-2-deoxy-D-glucose (18F-FDG) accumulation in neoplasms became commercially available in 1994. Besides conventional low-energy imaging in the collimated single-photon mode, it offers a relatively inexpensive opportunity to perform uncollimated PET by switching to the coincidence acquisition mode. This review summarises the clinical value of 18F-FDG detection with a dual-head coincidence camera in oncology. The results are compared with the overall results obtained using dedicated PET scanners. With respect to head and neck tumours, 18F-FDG coincidence mode gamma camera imaging (CGI) yields results that are in agreement with those obtained with dedicated PET scanners. With regard to other malignancies, such as lung cancer, lymphoma and brain tumours, data in the literature are too scarce to draw any definite conclusions. In general, the results of 18F-FDG CGI in tumours >15 mm seem to be comparable to those obtained with dedicated PET scanners, whereas in tumours <15 mm, the relative sensitivity of 18F-FDG CGI is approximately 80%. Using attenuation correction, the diagnostic yield of 18F-FDG CGI may increase. However, further clinical investigation is required to definitely establish its value in staging primary disease, therapy monitoring and assessment of tumour recurrence in clinical oncology.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11440038

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  2 in total

Review 1.  Impact of technology on the utilisation of positron emission tomography in lymphoma: current and future perspectives.

Authors:  D Visvikis; P J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-13       Impact factor: 9.236

2.  Value of laparoscopy and laparoscopic ultrasonography in determining resectability of colorectal hepatic metastases.

Authors:  M Gholghesaei; J M van Muiswinkel; J W Kuiper; G Kazemier; H W Tilanus; J N M Ijzermans
Journal:  HPB (Oxford)       Date:  2003       Impact factor: 3.647

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.