Literature DB >> 11439490

Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

F Verhaegen1, C Mubata, J Pettingell, A M Bidmead, I Rosenberg, D Mockridge, A E Nahum.   

Abstract

Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was used to model electron beams (6-20 MeV) from a Varian 2100C linear accelerator. After optimization of the Monte Carlo simulation model, agreement within 1% to 2% was obtained between calculated and measured (with a Si diode) lateral and depth dose distributions or within 1 mm in the penumbral regions. Output factors for square, rectangular, and circular fields were measured using two different plane-parallel ion chambers (Markus and NACP) and compared to MC simulations. The agreement was usually within 1% to 2%. This study was not primarily concerned with minimizing the simulation time required to obtain output factors but some considerations with respect to this are presented. It would be particularly useful if the MC model could also be used to calculate output factors for other, similar linacs. To see if this was possible, the primary electron energies in the MC model were retuned to model a recently commissioned similar linac. Good agreement between calculated and measured output factors was obtained for most field sizes for this second accelerator.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11439490     DOI: 10.1118/1.1373402

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Optimization of dual electron multileaf collimator materials by use of EGSnrc.

Authors:  Samuel O Inyang; Alan C Chamberlain
Journal:  Radiol Phys Technol       Date:  2010-05-13

2.  Monte Carlo simulations of electron beams collimated with a dual electron multileaf collimator: a feasibility study.

Authors:  S O Inyang; A C Chamberlain
Journal:  Radiol Phys Technol       Date:  2009-07-04

3.  Monte carlo model and output factors of elekta infinity™ 6 and 10 MV photon beam.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-28

4.  Design and evaluation of electron beam energy degraders for breast boost irradiation.

Authors:  Jong In Park; Sung Whan Ha; Jung-In Kim; Hyunseok Lee; Jaegi Lee; Il Han Kim; Sung-Joon Ye
Journal:  Radiat Oncol       Date:  2016-08-31       Impact factor: 3.481

5.  Monte Carlo calculations of output factors for clinically shaped electron fields.

Authors:  Julius V Turian; Brett D Smith; Damian A Bernard; Katherine L Griem; James C Chu
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

6.  Validation of Monte Carlo-based calculations for megavolt electron beams for IORT and FLASH-IORT.

Authors:  Graeme L Lazarus; Déte van Eeden; Frederik Cp du Plessis
Journal:  Heliyon       Date:  2022-09-19

7.  Application of a dummy eye shield for electron treatment planning.

Authors:  Sei-Kwon Kang; Soah Park; Taejin Hwang; Kwang-Ho Cheong; Taejin Han; Haeyoung Kim; Me-Yeon Lee; Kyoung Ju Kim; Do Hoon Oh; Hoonsik Bae
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

8.  Modeling the head of PRIMUS linear accelerator for electron-mode at 10 MeV for different applicators.

Authors:  Hani Negm; Moamen M O M Aly; Walaa M Fathy
Journal:  J Appl Clin Med Phys       Date:  2020-02-18       Impact factor: 2.102

  8 in total