A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit.

X Tang1, R Ning.   

Abstract

The circle-plus-arc orbit possesses advantages over other "circle-plus" orbits for the application of x-ray cone beam (CB) volume CT in image-guided interventional procedures requiring intraoperative imaging, in which movement of the patient table is to be avoided. A CB circle-plus-two-arc orbit satisfying the data sufficiency condition and a filtered backprojection (FBP) algorithm to reconstruct longitudinally unbounded objects is presented here. In the circle suborbit, the algorithm employs Feldkamp's formula and another FBP implementation. In the arc suborbits, an FBP solution is obtained originating from Grangeat's formula, and the reconstruction computation is significantly reduced using a window function to exclude redundancy in Radon domain. The performance of the algorithm has been thoroughly evaluated through computer-simulated phantoms and preliminarily evaluated through experimental data, revealing that the algorithm can regionally reconstruct longitudinally unbounded objects exactly and efficiently, is insensitive to the variation of the angle sampling interval along the arc suborbits, and is robust over practical x-ray quantum noise. The algorithm's merits include: only 1D filtering is implemented even in a 3D reconstruction, only separable 2D interpolation is required to accomplish the CB backprojection, and the algorithm structure is appropriate for parallel computation.

Entities:  

Mesh:

Year:  2001        PMID: 11439474     DOI: 10.1118/1.1376444

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Axial Cone-Beam Reconstruction by Weighted BPF/DBPF and Orthogonal Butterfly Filtering.

Authors:  Shaojie Tang; Xiangyang Tang
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-03       Impact factor: 4.538

2.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

3.  Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.

Authors:  J Webster Stayman; Sarah Capostagno; Grace J Gang; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-02

4.  Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study.

Authors:  Akira Matsuoka; Tomoaki Toyone; Ichiro Okano; Yoshifumi Kudo; Koji Ishikawa; Hiroshi Maruyama; Tomoyuki Ozawa; Toshiyuki Shirahata; Katsunori Inagaki
Journal:  BMC Musculoskelet Disord       Date:  2022-07-05       Impact factor: 2.562

5.  An efficient estimation method for reducing the axial intensity drop in circular cone-beam CT.

Authors:  Lei Zhu; Jared Starman; Rebecca Fahrig
Journal:  Int J Biomed Imaging       Date:  2008-10-08

6.  Circle plus partial helical scan scheme for a flat panel detector-based cone beam breast X-ray CT.

Authors:  Dong Yang; Ruola Ning; Weixing Cai
Journal:  Int J Biomed Imaging       Date:  2009-12-31