Literature DB >> 11438995

Biosensor technology for real-time detection of the cystic fibrosis W1282X mutation in CFTR.

G Feriotto1, A Ferlini, A Ravani, E Calzolari, C Mischiati, N Bianchi, R Gambari.   

Abstract

In the present paper, biospecific interaction analysis (BIA) was performed using surface plasmon resonance (SPR) and biosensor technologies to detect the Trp1282Ter mutation (W1282X) of the cystic fibrosis (CF) transmembrane conductance regulator (CFTR) gene. We first immobilized on a SA5 sensor chip a single-stranded biotinylated oligonucleotide containing the sequence involved in this mutation, and the efficiency of hybridization of oligonucleotide probes differing in length was determined. Second, we immobilized on different SA5 sensor chips biotinylated polymerase-chain reaction (PCR) products from a normal subject as well as from heterozygous and homozygous W1282X samples. The results obtained show that both allele-specific 10- and 12-mer oligonucleotides are suitable probes to detect W1282X mutations of the cystic fibrosis gene under standard BIA experimental conditions. During the association phase performed at 25 degrees C, discrimination between mismatched and full matched hybrids was readily and reproducibly observed by using the 10-mer W1282X probes. By contrast, when the 12-mer DNA probes were employed, discrimination between mismatched and full matched hybrids was observed during the dissociation phase. Taken together, the results presented suggest that BIA is an easy, speedy, and automatable approach to detect point mutations leading to cystic fibrosis. By this procedure, it is possible to perform real-time monitoring of hybridization between target single stranded PCR products obtained by using as substrates DNA isolated from normal or heterozygous subjects, and homozygous W1282X CF samples and oligonucleotide probes, therefore enabling a one-step, non-radioactive protocol to perform diagnosis. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11438995     DOI: 10.1002/humu.1151

Source DB:  PubMed          Journal:  Hum Mutat        ISSN: 1059-7794            Impact factor:   4.878


  2 in total

1.  Surface plasmon resonance and biosensor technology for real-time molecular diagnosis of beta o 39 thalassemia mutation.

Authors:  Giordana Feriotto; Giulia Breveglieri; Sara Gardenghi; Gianni Carandina; Roberto Gambari
Journal:  Mol Diagn       Date:  2004

Review 2.  Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease.

Authors:  Joanna L Richens; Richard A Urbanowicz; Elizabeth A M Lunt; Rebecca Metcalf; Jonathan Corne; Lucy Fairclough; Paul O'Shea
Journal:  Respir Res       Date:  2009-04-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.