Literature DB >> 11436210

Qualitative and quantitative analysis of regional left ventricular wall dynamics using real-time magnetic resonance imaging: comparison with conventional breath-hold gradient echo acquisition in volunteers and patients.

S Plein1, W H Smith, J P Ridgway, A Kassner, D J Beacock, T N Bloomer, M U Sivananthan.   

Abstract

A real-time magnetic resonance imaging (MRI) acquisition sequence was evaluated for the assessment of left ventricular wall motion (WM) and wall thickening (WT). Ten normal volunteers and 21 patients were studied. Short-axis cine images of the left ventricle (LV) were acquired with a fast gradient echo and an ultrafast segmented echo-planar imaging (EPI) sequence. Qualitative and quantitative analysis of WM and WT was performed on a segmental basis. Qualitative scores agreed between the two methods in 691 of 724 segments (95.4%) with good reproducibility. Quantitative measurements of WM and WT were significantly lower (P < 0.001) with the real-time method (WM: mean bias, 0.49 mm; WT: mean bias, 0.61 mm). The largest differences were observed in the anterior and lateral segments and in patients with dilated ventricles. The lower resolution of the real-time sequence and artifacts was probably responsible for these differences. In conclusion, real-time cardiac MRI can be used for qualitative assessment of wall dynamics but is presently insufficient for quantitative analysis. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11436210     DOI: 10.1002/jmri.1146

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

4.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

5.  Left ventricular function studied with MDCT.

Authors:  Kai Uwe Juergens; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

6.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

7.  Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

Authors:  Roman Fischbach; Kai Uwe Juergens; Murat Ozgun; David Maintz; Matthias Grude; Harald Seifarth; Walter Heindel; Thomas Wichter
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

8.  Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction.

Authors:  Michael S Hansen; Thomas S Sørensen; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

9.  Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

Authors:  Li Feng; Monvadi B Srichai; Ruth P Lim; Alexis Harrison; Wilson King; Ganesh Adluru; Edward V R Dibella; Daniel K Sodickson; Ricardo Otazo; Daniel Kim
Journal:  Magn Reson Med       Date:  2012-08-06       Impact factor: 4.668

10.  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.

Authors:  Peter Kellman; Christophe Chefd'hotel; Christine H Lorenz; Christine Mancini; Andrew E Arai; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.