PURPOSE: To investigate efficacy of stent-graft repair for the treatment of patients with chronic aortic dissection.
MATERIALS AND METHODS: Fifteen patients with chronic aortic dissection were treated with endovascular stent-grafts. Entry tears were located in the descending thoracic aorta in all patients. The mean maximum diameter of the descending thoracic aorta was 47 mm +/- 8. The mean diameter of the true lumen at the same level was 20 mm +/- 5. The mean interval between diagnosis and stent-graft procedure was 32 months +/- 91. Stent-grafts were fabricated from expanded polytetrafluoroethylene and Z-stents.
RESULTS: Stent-grafts were placed successfully in all patients. Two stent-grafts were required in one patient. Entry closure and thrombosis of the false lumen of the descending thoracic aorta were also achieved in all patients. No procedure-related complications were observed except for postimplantation syndrome, including fever and leukocytosis. The diameter of the true lumen was significantly increased (mean, 31 mm +/- 6) at the level of the descending thoracic aorta (P <.01) and the diameter of the aorta was significantly decreased (mean, 44 mm +/- 8) at the same level (P <.01). There were no deaths and no instances of aortic rupture during the subsequent average follow-up period of 24 months. Secondary stent-graft procedures were required to treat the abdominal component of dissection during follow-up in one patient.
CONCLUSIONS: Stent-graft repair of chronic aortic dissection is a safe and effective method and may be an alternative to surgical graft replacement in selected patients. However, further evaluation is mandatory before this method is widely employed.

Entities:  

Mesh:

Year:  2001        PMID: 11435539     DOI: 10.1016/s1051-0443(07)61508-5

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  2 in total

Review 1.  TEVAR: the solution to all aortic problems?

Authors:  I Akin; S Kische; T C Rehders; H Schneider; H Ince; C A Nienaber
Journal:  Herz       Date:  2011-09       Impact factor: 1.443

2.  Midterm results for endovascular stent grafts via median sternotomy for distal aortic arch aneurysm.

Authors:  Koji Sakurai; Akihiko Usui; Yuuichi Ueda; Toshiaki Akita; Masaharu Yoshikawa; Hiroomi Murayama; Tsuneo Ishiguchi; Kazuki Tajima
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.