A controlled comparison of traditional feeding tube verification methods to a bedside, electromagnetic technique.

P J Kearns1, C Donna.   

Abstract

BACKGROUND: Benefits of enteral feeding are diminished by aspiration pneumonia and mechanical complications of misplaced feeding tubes. To avoid complications, clinicians determine the location of the tip before feeding. This study compares diagnostic test characteristics of 4 techniques for tip localization.
METHODS: A prospective, blinded trial was conducted on the wards and critical care units of four acute-care hospitals. Patients requiring at least 3 days of enteral feeding were studied. Four observers at each institution used a randomly assigned technique to determine a tube's tip location. Methods included auscultation, aspiration with inspection or pH determination of aspirated material, and a recently developed electromagnetic technique. Results were compared with radiographic determination. Success rates were compared using sensitivity, specificity, and likelihood ratios.
RESULTS: The 4 methods agreed with the radiograph in (mean, 95% confidence interval): 84 (80 to 88)%, 50 (45 to 55)%, 56 (51 to 61)%, and 76 (72 to 81)% of observations, respectively. Only the electromagnetic method and aspiration identified all tubes located above the diaphragm (negative likelihood ratio 0 and sensitivity 100%). Aspiration was unsuccessful in making a determination in 53% of the observations, whereas the electromagnetic method was successful 90% of the time.

Entities:  

Mesh:

Year:  2001        PMID: 11434652     DOI: 10.1177/0148607101025004210

Source DB:  PubMed          Journal:  JPEN J Parenter Enteral Nutr        ISSN: 0148-6071            Impact factor:   4.016


  3 in total

1.  The placement of nasogastric tubes.

Authors:  Malcolm Lemyze
Journal:  CMAJ       Date:  2010-03-29       Impact factor: 8.262

Review 2.  Naso-enteric Tube Placement: A Review of Methods to Confirm Tip Location, Global Applicability and Requirements.

Authors:  S A Milsom; J A Sweeting; H Sheahan; E Haemmerle; J A Windsor
Journal:  World J Surg       Date:  2015-09       Impact factor: 3.352

3.  Accuracy of the combined method (auscultation and pH measurement) and ultrasonography for confirmation of gastric tube placement: a study protocol for a prospective study.

Authors:  Mayara Carvalho Godinho Rigobello; Jorge Elias Junior; Carlos Alberto Grespan Bonacim; Renata Cristina de Campos Pereira Silveira; Fernanda Caroline Bonardi; Roosevelt Santos Nunes; Rosana Aparecida Pereira; Fernanda Raphael Escobar Gimenes
Journal:  BMJ Open       Date:  2020-09-30       Impact factor: 2.692

  3 in total