Literature DB >> 11434355

Clinical significance of the fractional excretion of anions in metabolic acidosis.

H Y Kim1, J S Han, U S Jeon, K W Joo, J H Earm, C Ahn, S Kim, J S Lee, G H Kim.   

Abstract

The fractional excretion of anions has been proposed as a new index for the differential diagnosis of metabolic acidosis, identifying the properties of the conjugate base by examining the renal handling of the anion. Here, we investigated clinical significance of the fractional excretion of anions in pathophysiologic diagnosis of metabolic acidosis by measuring urine ammonium (NH4+) excretion, the ratio of A plasma anion gap/delta plasma HCO3- concentration (deltaAG/deltaHCO3-), and fractional excretion of anions in three different groups of metabolic acidosis: acid overproduction (8 patients with lactic acidosis, 8 with diabetic ketoacidosis, 3 with hippuric acidosis following glue sniffing), acid underexcretion (10 patients with chronic renal failure) and normal controls (10 normal volunteers who underwent 3-day NH4Cl loading). As expected, urine NH4+ excretion was higher in overproduction acidosis than in acid-loaded normal controls (88.1 +/- 12.3 vs. 54.0 +/- 3.7 mmol/day, p < 0.05), and it was lower in chronic renal failure than in acid-loaded normal controls (12.8 +/- 1.7 vs. 54.0 +/- 3.7 mmol/day, p < 0.05). The fractional excretion of anions had no difference between overproduction acidosis and chronic renal failure (41.2 +/- 42.8% vs. 41.0 +/- 8.1%). However, the fractional excretion of anions showed significant differences between the subgroups in acid overproduction (lactic acidosis, 4.7 +/- 0.3%; diabetic ketoacidosis, 45.8 +/- 3.1%; hippuric acidosis, 126.0 +/- 14.4%; p < 0.05). The ratio of plasma deltaAG/deltaHCO3- also exhibited significant differences between the subgroups in acid overproduction (lactic acidosis, 1.5 +/- 0.1; diabetic ketoacidosis, 1.0 +/- 0.1; hippuric acidosis, 0.3 +/- 0.1; p < 0.05). There was an inverse linear correlation between the fractional excretion of anions and the ratio of plasma deltaAG/deltaHCO3- (r2 =-0.89, p < 0.05). In conclusion, determination of the fractional excretion of anions may provide a useful clue to the differential diagnosis of metabolic acidosis caused by acid overproduction.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11434355

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975


  4 in total

Review 1.  The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?

Authors:  Jeffrey A Kraut; Glenn T Nagami
Journal:  Clin J Am Soc Nephrol       Date:  2013-07-05       Impact factor: 8.237

Review 2.  Metabolic acidosis: pathophysiology, diagnosis and management.

Authors:  Jeffrey A Kraut; Nicolaos E Madias
Journal:  Nat Rev Nephrol       Date:  2010-03-23       Impact factor: 28.314

3.  The Δ Anion Gap/Δ Bicarbonate Ratio in Early Lactic Acidosis: Time for Another Delta?

Authors:  Scott E Rudkin; Tristan R Grogan; Richard M Treger
Journal:  Kidney360       Date:  2020-11-10

Review 4.  Diagnosis and management of metabolic acidosis: guidelines from a French expert panel.

Authors:  Boris Jung; Mikaël Martinez; Yann-Erick Claessens; Michaël Darmon; Kada Klouche; Alexandre Lautrette; Jacques Levraut; Eric Maury; Mathieu Oberlin; Nicolas Terzi; Damien Viglino; Youri Yordanov; Pierre-Géraud Claret; Naïke Bigé
Journal:  Ann Intensive Care       Date:  2019-08-15       Impact factor: 6.925

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.