Literature DB >> 11432270

Measuring the CO2 flux at the air/water interface in lakes using flow injection analysis.

F V Almeida1, J R Guimarães, W F Jardim.   

Abstract

The carbon dioxide flux at the air/water interface in lakes was calculated after the determination of H2CO3* (free CO2) and atmospheric CO2 using flow injection analysis (FIA) coupled to a conductometric detector. The method is based on the diffusion of CO2 through a hydrophobic membrane into a flow of deionized water, generating a gradient of conductivity proportional to the concentration of CO2 in the sample. Using one experimental set-up, the speciation of the inorganic carbon (H2CO3* and dissolved inorganic carbon) was accomplished by simply adjusting the sample pH. The determination of CO2 in the atmosphere was carried out by direct injection of the gaseous samples. The FIA apparatus was taken into the field and CO2 fluxes were evaluated in several Brazilian lakes. In these lakes, representing different eutrophic stages, the CO2 flux varied from -242 (invasive) up to 3227 (evasive) mumol CO2 m-2 h-1.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11432270     DOI: 10.1039/b010065j

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  1 in total

1.  The Relative Performance of NDIR-based Sensors in the Near Real-time Analysis of CO₂ in Air.

Authors:  Sudhir Kumar Pandey; Ki-Hyun Kim
Journal:  Sensors (Basel)       Date:  2007-09-03       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.