PURPOSE: To evaluate the role of helical CT in the evaluation of skull abnormalities seen in fibrous dysplasia.
MATERIALS AND METHODS: Prospective study on 6 cases with cranio-facial fibrous dysplasia (3 males and 3 females) aged 8 to 59 years old, evaluated with plain radiographs, helical CT and, in 1 case, MRI. Helical CT was performed in 3 cases on a CT Twin scan (Elscint), in 3 cases on a Somatom Plus scan (Siemens). Multiplanar reconstructions and 3D reconstructions were done in all cases. 4 cases had a histopathological confirmation of fibrous dysplasia lesions by bone-biopsy (3 cases) or surgical biopsy (1 case).
RESULTS: The 6 cases included sclerotic form in 3 cases, cystic variety in 1 case, polyostotic variety in 1 case, mixed form in 1 case. Topographic localizations of fibrous dysplasia were skull base involvement in 1 case, multizonal skull involvement in 4 cases, maxillo-mandibulary involvement (cherubism) in 1 case.
CONCLUSION: Helical CT is an optimal method to evaluate the skull lesions of fibrous dysplasia. The review of source images must always be done. 3-dimensional bone reconstructions are better to visualize the anterior cranial vault and skull base dysmorphy. Helical acquisition is a compromise in case by case between the dose of irradiation and the quality of source images.

Entities:  

Mesh:

Year:  2001        PMID: 11428209

Source DB:  PubMed          Journal:  J Radiol        ISSN: 0221-0363


  2 in total

1.  Fibrous dysplasia of the maxilla: diagnostic reliability of the study image. Literature review.

Authors:  Massimo Fusconi; Michela Conte; Martina Pagliarella; Chiara De Vincentiis; Armando De Virgilio; Anna Teresa Benincasa; Simone Alessi; Andrea Gallo
Journal:  J Neurol Surg B Skull Base       Date:  2013-06-13

2.  Fibrous Dysplasia Characterization Using Lacunarity Analysis.

Authors:  Mirna S Cordeiro; André R Backes; Antônio F Durighetto Júnior; Elmar H G Gonçalves; Jefferson X de Oliveira
Journal:  J Digit Imaging       Date:  2016-02       Impact factor: 4.056