Literature DB >> 11427937

Optical method for the determination of the oxygen-transfer capacity of small bioreactors based on sulfite oxidation.

R Hermann1, N Walther, U Maier, J Büchs.   

Abstract

The growth of microorganisms may be limited by operating conditions which provide an inadequate supply of oxygen. To determine the oxygen-transfer capacities of small-scale bioreactors such as shaking flasks, test tubes, and microtiter plates, a noninvasive easy-to-use optical method based on sulfite oxidation has been developed. The model system of sodium sulfite was first optimized in shaking-flask experiments for this special application. The reaction conditions (pH, buffer, and catalyst concentration) were adjusted to obtain a constant oxygen transfer rate for the whole period of the sulfite oxidation reaction. The sharp decrease of the pH at the end of the oxidation, which is typical for this reaction, is visualized by adding a pH dye and used to measure the length of the reaction period. The oxygen-transfer capacity can then be calculated by the oxygen consumed during the complete stoichiometric transformation of sodium sulfite and the visually determined reaction time. The suitability of this optical measuring method for the determination of oxygen-transfer capacities in small-scale bioreactors was confirmed with an independent physical method applying an oxygen electrode. The correlation factor for the maximum oxygen-transfer capacity between the chemical model system and a culture of Pseudomonas putida CA-3 was determined in shaking flasks. The newly developed optical measuring method was finally used for the determination of oxygen-transfer capacities of different types of transparent small-scale bioreactors. Copyright 2001 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11427937     DOI: 10.1002/bit.1126

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  10 in total

1.  Optimization of melanin pigment production from the halotolerant black yeast Hortaea werneckii AS1 isolated from solar salter in Alexandria.

Authors:  Asmaa Elsayis; Sahar W M Hassan; Khaled M Ghanem; Heba Khairy
Journal:  BMC Microbiol       Date:  2022-04-08       Impact factor: 3.605

2.  Implementation of Perforated Concentric Ring Walls Considerably Improves Gas-Liquid Mass Transfer of Shaken Bioreactors.

Authors:  Sven Hansen; Andreas Gumprecht; Linda Micheel; Hans-Georg Hennemann; Franziska Enzmann; Wilfried Blümke
Journal:  Front Bioeng Biotechnol       Date:  2022-05-12

3.  Scale-up from microtiter plate to laboratory fermenter: evaluation by online monitoring techniques of growth and protein expression in Escherichia coli and Hansenula polymorpha fermentations.

Authors:  Frank Kensy; Christoph Engelbrecht; Jochen Büchs
Journal:  Microb Cell Fact       Date:  2009-12-22       Impact factor: 5.328

4.  Potential errors in conventional DOT measurement techniques in shake flasks and verification using a rotating flexitube optical sensor.

Authors:  Sven Hansen; Frank Kensy; Andreas Käser; Jochen Büchs
Journal:  BMC Biotechnol       Date:  2011-05-11       Impact factor: 2.563

5.  Comprehensive clone screening and evaluation of fed-batch strategies in a microbioreactor and lab scale stirred tank bioreactor system: application on Pichia pastoris producing Rhizopus oryzae lipase.

Authors:  Johannes Hemmerich; Núria Adelantado; José Manuel Barrigón; Xavier Ponte; Astrid Hörmann; Pau Ferrer; Frank Kensy; Francisco Valero
Journal:  Microb Cell Fact       Date:  2014-03-07       Impact factor: 5.328

6.  Recombinant production of the antibody fragment D1.3 scFv with different Bacillus strains.

Authors:  Antonia Lakowitz; Rainer Krull; Rebekka Biedendieck
Journal:  Microb Cell Fact       Date:  2017-01-23       Impact factor: 5.328

7.  Validation of a high-throughput fermentation system based on online monitoring of biomass and fluorescence in continuously shaken microtiter plates.

Authors:  Frank Kensy; Emerson Zang; Christian Faulhammer; Rung-Kai Tan; Jochen Büchs
Journal:  Microb Cell Fact       Date:  2009-06-04       Impact factor: 5.328

8.  Combination of On-line pH and Oxygen Transfer Rate Measurement in Shake Flasks by Fiber Optical Technique and Respiration Activity MOnitoring System (RAMOS).

Authors:  Marco Scheidle; Johannes Klinger; Jochen Büchs
Journal:  Sensors (Basel)       Date:  2007-12-20       Impact factor: 3.576

9.  Cross-section perimeter is a suitable parameter to describe the effects of different baffle geometries in shaken microtiter plates.

Authors:  Clemens Lattermann; Matthias Funke; Sven Hansen; Sylvia Diederichs; Jochen Büchs
Journal:  J Biol Eng       Date:  2014-07-15       Impact factor: 4.355

10.  Customized microscale approach for optimizing two-phase bio-oxidations of alkanes with high reproducibility.

Authors:  Johannes F Kolmar; Oliver Thum; Frank Baganz
Journal:  Microb Cell Fact       Date:  2017-10-10       Impact factor: 5.328

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.