Literature DB >> 11425688

Effects of rigid and soft contact lens daily wear on corneal epithelium, tear lactate dehydrogenase, and bacterial binding to exfoliated epithelial cells.

P M Ladage1, K Yamamoto, D H Ren, L Li, J V Jester, W M Petroll, H D Cavanagh.   

Abstract

OBJECTIVE: To determine the effects of lens type and oxygen transmissibility on human corneal epithelium during daily lens wear (DW).
DESIGN: Prospective, randomized, double-masked, single-center, parallel treatment groups clinical trial. PARTICIPANTS: Two hundred forty-six patients fitted with: (1) high oxygen-transmissible soft lenses (n = 36), (2) hyper oxygen-transmissible soft lenses (n = 135), and (3) hyper oxygen-transmissible rigid gas-permeable (RGP) lenses (n = 75). INTERVENTION: Irrigation chamber to collect exfoliated epithelial surface cells, confocal microscopy, and tear collection at baseline, 2 weeks, and 4 weeks of DW. MAIN OUTCOME MEASURES: (1) Pseudomonas aeruginosa (PA) binding to exfoliated corneal epithelial surface cells, (2) central epithelial thickness, (3) superficial epithelial cell area, (4) epithelial surface cell exfoliation, and (5) tear lactate dehydrogenase (LDH).
RESULTS: Four weeks of DW with the high oxygen-transmissible soft lens significantly increased PA binding from baseline 6.55 +/- 3.01 to 8.75 +/- 3.05 bacteria per epithelial cell (P < 0.01). By contrast, hyper oxygen-transmissible soft lens wear increased binding significantly less (6.13 +/- 2.45 to 7.62 +/- 3.06; P < 0.01), whereas hyper oxygen-transmissible RGP lens wear demonstrated no significant changes (5.91 +/- 2.40 to 6.13 +/- 2.17; P = 0.533). No significant change in central epithelial thickness was found after 4 weeks of DW in either soft lens; however, the epithelial thickness decreased by 9.8% (P < 0.001) with RGP lens wear. Epithelial cell surface area increased 3.3% and 4.1% with the high and hyper oxygen-transmissible soft lenses, respectively, and 10.5% with the hyper oxygen-transmissible RGP lens (P < 0.001). Epithelial desquamation significantly decreased in all groups (P < 0.001). Tear LDH levels increased for all test lenses (P < 0.001).
CONCLUSIONS: Increased PA binding induced by wear of a conventional soft lens material is significantly greater than that induced by the new hyper oxygen-transmissible soft silicone hydrogel lens during DW. However, both soft materials showed significant increases in PA binding as compared with baseline controls. By contrast, hyper oxygen-transmissible RGP lens DW did not increase PA binding significantly. Taken together, these findings suggest for the first time both an oxygen effect as well as a difference between soft and rigid lens types on PA binding in DW.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11425688     DOI: 10.1016/s0161-6420(01)00639-x

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  29 in total

Review 1.  In vivo confocal microscopy of the human cornea.

Authors:  I Jalbert; F Stapleton; E Papas; D F Sweeney; M Coroneo
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

2.  Risk factors for corneal infiltrative events during continuous wear of silicone hydrogel contact lenses.

Authors:  Loretta Szczotka-Flynn; Jonathan H Lass; Ajay Sethi; Sara Debanne; Beth Ann Benetz; Matthew Albright; Beth Gillespie; Jana Kuo; Michael R Jacobs; Alfred Rimm
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-10       Impact factor: 4.799

3.  Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2008-06       Impact factor: 3.573

Review 4.  In Vivo Confocal Microscopy of the Cornea: New Developments in Image Acquisition, Reconstruction, and Analysis Using the HRT-Rostock Corneal Module.

Authors:  W Matthew Petroll; Danielle M Robertson
Journal:  Ocul Surf       Date:  2015-05-18       Impact factor: 5.033

Review 5.  In vivo confocal microscopy of the ocular surface: from bench to bedside.

Authors:  Edoardo Villani; Christophe Baudouin; Nathan Efron; Pedram Hamrah; Takashi Kojima; Sanjay V Patel; Stephen C Pflugfelder; Andrey Zhivov; Murat Dogru
Journal:  Curr Eye Res       Date:  2013-11-11       Impact factor: 2.424

Review 6.  Dry eye disease and microbial keratitis: is there a connection?

Authors:  Srihari Narayanan; Rachel L Redfern; William L Miller; Kelly K Nichols; Alison M McDermott
Journal:  Ocul Surf       Date:  2013-01-29       Impact factor: 5.033

7.  Rat silicone hydrogel contact lens model: effects of high- versus low-Dk lens wear.

Authors:  Yunfan Zhang; Manal M Gabriel; Mary F Mowrey-McKee; Ronald P Barrett; Sharon McClellan; Linda D Hazlett
Journal:  Eye Contact Lens       Date:  2008-11       Impact factor: 2.018

8.  Remote-controlled scanning and automated confocal microscopy through focusing using a modified HRT rostock corneal module.

Authors:  W Matthew Petroll; H Dwight Cavanagh
Journal:  Eye Contact Lens       Date:  2009-11       Impact factor: 2.018

9.  Treatment, material, care, and patient-related factors in contact lens-related dry eye.

Authors:  Padmapriya Ramamoorthy; Loraine T Sinnott; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2008-08       Impact factor: 1.973

10.  A two-week clinical evaluation of the safety of Systane Ultra in contact lens-wearing patients.

Authors:  David Kading
Journal:  Clin Ophthalmol       Date:  2010-02-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.