OBJECTIVE: Previous tissue engineering approaches to create small caliber vascular grafts have been limited by the structural and mechanical immaturity of the constructs. This study uses a novel in vitro pulse duplicator system providing a 'biomimetic' environment during tissue formation to yield more mature, implantable vascular grafts. METHODS: Vascular grafts (I.D. 0.5 cm) were fabricated from novel bioabsorbable polymers (polyglycolic-acid/poly-4-hydroxybutyrate) and sequentially seeded with ovine vascular myofibroblasts and endothelial cells. After 4 days static culture, the grafts (n=24) were grown in vitro in a pulse duplicator system (bioreactor) for 4, 7, 14, 21, and 28 days. Controls (n=24) were grown in static culture conditions. Analysis of the neo-tissue included histology, scanning electron microscopy (SEM), and biochemical assays (DNA for cell content, 5-hydroxyproline for collagen). Mechanical testing was performed measuring the burst pressure and the suture retention strength. RESULTS: Histology showed viable, dense tissue in all samples. SEM demonstrated confluent smooth inner surfaces of the grafts exposed to pulsatile flow after 14 days. Biochemical analysis revealed a continuous increase of cell mass and collagen to 21 days compared to significantly lower values in the static controls. The mechanical properties of the pulsed vascular grafts comprised supra-physiological burst strength and suture retention strength appropriate for surgical implantation. CONCLUSIONS: This study demonstrates the feasibility of tissue engineering of viable, surgically implantable small caliber vascular grafts and the important effect of a 'biomimetic' in vitro environment on tissue maturation and extracellular matrix formation.
OBJECTIVE: Previous tissue engineering approaches to create small caliber vascular grafts have been limited by the structural and mechanical immaturity of the constructs. This study uses a novel in vitro pulse duplicator system providing a 'biomimetic' environment during tissue formation to yield more mature, implantable vascular grafts. METHODS: Vascular grafts (I.D. 0.5 cm) were fabricated from novel bioabsorbable polymers (polyglycolic-acid/poly-4-hydroxybutyrate) and sequentially seeded with ovine vascular myofibroblasts and endothelial cells. After 4 days static culture, the grafts (n=24) were grown in vitro in a pulse duplicator system (bioreactor) for 4, 7, 14, 21, and 28 days. Controls (n=24) were grown in static culture conditions. Analysis of the neo-tissue included histology, scanning electron microscopy (SEM), and biochemical assays (DNA for cell content, 5-hydroxyproline for collagen). Mechanical testing was performed measuring the burst pressure and the suture retention strength. RESULTS: Histology showed viable, dense tissue in all samples. SEM demonstrated confluent smooth inner surfaces of the grafts exposed to pulsatile flow after 14 days. Biochemical analysis revealed a continuous increase of cell mass and collagen to 21 days compared to significantly lower values in the static controls. The mechanical properties of the pulsed vascular grafts comprised supra-physiological burst strength and suture retention strength appropriate for surgical implantation. CONCLUSIONS: This study demonstrates the feasibility of tissue engineering of viable, surgically implantable small caliber vascular grafts and the important effect of a 'biomimetic' in vitro environment on tissue maturation and extracellular matrix formation.
Authors: Dong Hwa Kim; Su-Jin Heo; Yun Gyeong Kang; Ji Won Shin; So Hee Park; Jung-Woog Shin Journal: J Mater Sci Mater Med Date: 2016-01-22 Impact factor: 3.896
Authors: John J Stankus; Lorenzo Soletti; Kazuro Fujimoto; Yi Hong; David A Vorp; William R Wagner Journal: Biomaterials Date: 2007-02-20 Impact factor: 12.479
Authors: Leah Soffer; Xianyan Wang; Xiaohui Zhang; Jonathan Kluge; Luis Dorfmann; David L Kaplan; Gary Leisk Journal: J Biomater Sci Polym Ed Date: 2008 Impact factor: 3.517
Authors: Xiaohui Zhang; Xiuli Wang; Vinny Keshav; Xiaoqin Wang; Jacqueline T Johanas; Gary G Leisk; David L Kaplan Journal: Biomaterials Date: 2009-02-20 Impact factor: 12.479