Literature DB >> 11422230

Low level leucocyte counting: a critical variable in the validation of leucodepleted blood transfusion components as highlighted by an external quality assessment study.

D Barnett1, K Goodfellow, J Ginnever, V Granger, L Whitby, J T Reilly.   

Abstract

Leucocyte counts of < 5 x 106 per blood transfusion product are currently recommended in the UK in order to reduce transfusion-related infections and febrile reactions. Routine leucocyte depletion, however, requires the development of reliable internal and external quality assurance (EQA) programmes. We report preliminary findings from the UK NEQAS for Low-Level Leucocyte Counting from 18 UK Transfusion Centres over a four month period. Data analysis showed that the IMAGN 2000 had the lowest CVs (range 7.5-36%, mean 16.7) for samples with counts of 5-30 cells/microl when compared to the flow cytometric (range 13.8-88%, mean 29.5) and Nageotte methods (range 20.6-117%, mean 61.8). In addition, laboratories using commercial nuclear stains (LeucoCOUNTTM) had consistently lower CVs than those using 'in-house' propidium iodide staining methods. Important differences in flow cytometric gating strategies were also identified. This study highlights the current variability in low level leucocyte counting, especially within the critical range of 5-30 cells/microl (equating to < 5 x 106/l). The acceptance of consensus protocols, including gating strategies and nuclear staining techniques, is required to reduce the observed interlaboratory variation. Finally, we demonstrate that stabilized blood preparations can be successfully used to provide a national/international low-level leucocyte EQA scheme.

Entities:  

Mesh:

Year:  2001        PMID: 11422230     DOI: 10.1046/j.1365-2257.2001.00356.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  4 in total

1.  Leukoreduced blood components: Advantages and strategies for its implementation in developing countries.

Authors:  R R Sharma; Neelam Marwaha
Journal:  Asian J Transfus Sci       Date:  2010-01

2.  Release of cytokines in stored whole blood and red cell concentrate: Effect of leukoreduction.

Authors:  Rinku Shukla; Tanvi Patel; Snehalata Gupte
Journal:  Asian J Transfus Sci       Date:  2015 Jul-Dec

3.  The use of a hematology analyzer with a new generation of software as an alternative to flow cytometry for enumerating residual white blood cells in blood components.

Authors:  Richard Alejo Blanco; Chloe Cavagnetto; Laura Willmott; Elif Aydogdu; Nicola Akinyemi; Helena Standring; Simon Procter; Stephen F Garner; Atsushi Shirakami; Jarob Saker; Joachim Linssen; Rebecca Cardigan
Journal:  Transfusion       Date:  2019-11-26       Impact factor: 3.157

4.  Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study.

Authors:  Yang Zeng; Michelle Dabay; Virginia George; Shalini Seetharaman; Monika de Arruda Indig; Sharon Graminske; Nicole Kimpel; Anna Schmidt; Amanda Boerner; Sarai Paradiso; Tatyana Delman; Yunyao Li; Viktoriya Litvak; Farzad Oreizy; Angela Chen; Maryam Saleminik; Fred Mosqueda; Anna Lin; Kevin Judge
Journal:  Cytometry A       Date:  2018-01-18       Impact factor: 4.355

  4 in total