Analysis of fractal dimensions of rat bones from film and digital images.

S Pornprasertsuk1, J B Ludlow, R L Webber, D A Tyndall, M Yamauchi.   

Abstract

OBJECTIVES: (1) To compare the effect of two different intra-oral image receptors on estimates of fractal dimension; and (2) to determine the variations in fractal dimensions between the femur, tibia and humerus of the rat and between their proximal, middle and distal regions.
METHODS: The left femur, tibia and humerus from 24 4-6-month-old Sprague-Dawley rats were radiographed using intra-oral film and a charge-coupled device (CCD). Films were digitized at a pixel density comparable to the CCD using a flat-bed scanner. Square regions of interest were selected from proximal, middle, and distal regions of each bone. Fractal dimensions were estimated from the slope of regression lines fitted to plots of log power against log spatial frequency.
RESULTS: The fractal dimensions estimates from digitized films were significantly greater than those produced from the CCD (P=0.0008). Estimated fractal dimensions of three types of bone were not significantly different (P=0.0544); however, the three regions of bones were significantly different (P=0.0239). The fractal dimensions estimated from radiographs of the proximal and distal regions of the bones were lower than comparable estimates obtained from the middle region.
CONCLUSIONS: Different types of image receptors significantly affect estimates of fractal dimension. There was no difference in the fractal dimensions of the different bones but the three regions differed significantly.

Entities:  

Keywords:  NASA Discipline Musculoskeletal; Non-NASA Center

Mesh:

Year:  2001        PMID: 11420632     DOI: 10.1038/sj/dmfr/4600597

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  Image resolution and exposure time of digital radiographs affects fractal dimension of periapical bone.

Authors:  B Güniz Baksi; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2011-11-29       Impact factor: 3.573

2.  Effect of bisphosphonate treatment on the jawbone: an exploratory study using periapical and panoramic radiographic evaluation.

Authors:  Imad Barngkgei; Esam Halboub; Abeer Almashraqi
Journal:  Oral Radiol       Date:  2018-11-07       Impact factor: 1.852

Review 3.  Use of fractal analysis in dental images for osteoporosis detection: a systematic review and meta-analysis.

Authors:  R Franciotti; M Moharrami; A Quaranta; M E Bizzoca; A Piattelli; G Aprile; V Perrotti
Journal:  Osteoporos Int       Date:  2021-01-28       Impact factor: 4.507

4.  A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site.

Authors:  Tomasz Kulczyk; Agata Czajka-Jakubowska; Agnieszka Przystańska
Journal:  Biomed Res Int       Date:  2018-10-15       Impact factor: 3.411

5.  Effect of Image Resolution and Compression on Fractal Analysis of the Periapical Bone.

Authors:  Shiva Toghyani; Ibrahim Nasseh; Georges Aoun; Marcel Noujeim
Journal:  Acta Inform Med       Date:  2019-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.