Literature DB >> 11417510

Immobilization devices for intensity-modulated radiation therapy (IMRT).

C B Saw1, R Yakoob, C A Enke, T P Lau, K M Ayyangar.   

Abstract

Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans show radiation dose distribution that is highly conformal to the target volume. The successful clinical implementation of these radiotherapy modalities requires precise positioning of the target to avoid a geographical miss. Effective reduction in target positional inaccuracies can be achieved with the proper use of immobilization devices. This paper reviews some of the immobilization devices that have been used and/or have the potential of being used for IMRT. The immobilization devices being reviewed include stereotactic frame, Talon system, thermoplastic molds, Alpha Cradles, and Vac-Lok system. The implementation of these devices at various anatomical sites is discussed.

Mesh:

Year:  2001        PMID: 11417510     DOI: 10.1016/s0958-3947(00)00059-5

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  5 in total

1.  Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

Authors:  Manju Sharma; Troy Dos Santos; Nikolaos P Papanikolopoulos; Susanta Kumar Hui
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

Review 2.  The evolving role of stereotactic radiosurgery and stereotactic radiation therapy for patients with spine tumors.

Authors:  Jack P Rock; Samuel Ryu; Fang-Fang Yin; Faye Schreiber; Muwaffak Abdulhak
Journal:  J Neurooncol       Date:  2004 Aug-Sep       Impact factor: 4.130

3.  A comparison of two systems of patient immobilization for prostate radiotherapy.

Authors:  Peter White; Chui Ka Yee; Lee Chi Shan; Lee Wai Chung; Ng Ho Man; Yik Shing Cheung
Journal:  Radiat Oncol       Date:  2014-01-22       Impact factor: 3.481

4.  Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer.

Authors:  He Wang; Congjun Wang; Samuel Tung; Andrew Wilson Dimmitt; Pei Fong Wong; Mark A Edson; Adam S Garden; David I Rosenthal; Clifton D Fuller; Gary B Gunn; Vinita Takiar; Xin A Wang; Dershan Luo; James N Yang; Jennifer Wong; Jack Phan
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

5.  Standard Operating Procedure (SOP) for mould room practices and simulation of head neck cancer patients undergoing proton therapy.

Authors:  Utpal Gaikwad; Minnal Mookaiah; S Karthekeyan; Manoj Wakde; M P Noufal; Srinivas Chilukuri; Dayananda Sharma; Rakesh Jalali; Sapna Nangia
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-09-30