Literature DB >> 11416821

Posterior disk displacement: morphologic assessment and measurement reliability-lumbar spine.

J R Cooley1, C D Danielson, G D Schultz, T A Hall.   

Abstract

BACKGROUND: Magnetic resonance imaging is often used to assess for disk displacement after manipulation, but limited information about the true incidence of iatrogenic herniations exists. To design a study that evaluates for a causal relationship, preliminary data must be obtained relating to the size of different types of disk displacement. The reliability of chiropractic radiologists in assessing disks and a comparison of different measuring devices should also be evaluated.
OBJECTIVE: To identify average measurements for normal and displaced disks and to assess the reliability of measurements by chiropractic radiologists. STUDY
DESIGN: Intraobserver and interobserver reliability study assessing disk displacement on magnetic resonance scans.
METHODS: Three evaluators assessed the disks on 122 magnetic resonance scans from two imaging centers. Six categories were graded, and digitizer and ruler measurements were compared. Forty-four scans were reassessed for intraobserver agreement. Intraobserver and interobserver variations were measured with intraclass correlation coefficient and kappa statistical analysis. Measurement device correlation was assessed with Pearson's r.
RESULTS: Clear size differences between different types of disk displacement were noted. Interexaminer measurement reliability was 0.78 to 0.84. Agreement concerning the presence of disk displacement was 85% (kappa = 0.68), and the classification of disk displacements was 76% (kappa = 0.60). Intraexaminer measurement reliability was 0.40 to 0.49. Intraexaminer agreement concerning the presence of disk displacement was 76% (kappa = 0.52), and the classification of disk displacements was 62% to 69% (kappa = 0.38 to 0.46). Normal versus bulged disk distinctions demonstrated the most disagreement. The ruler and digitizer correlation coefficient was 0.968.
CONCLUSIONS: Different disk types demonstrated distinct size averages. Interexaminer agreement was good concerning disk assessment and measurements. Intraexaminer agreement was lower than expected. A millimetric ruler is an acceptable alternative to digital measurement devices.

Entities:  

Mesh:

Year:  2001        PMID: 11416821     DOI: 10.1067/mmt.2001.115266

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  3 in total

Review 1.  Potential of magnetic resonance imaging findings to refine case definition for mechanical low back pain in epidemiological studies: a systematic review.

Authors:  Alison Endean; Keith T Palmer; David Coggon
Journal:  Spine (Phila Pa 1976)       Date:  2011-01-15       Impact factor: 3.468

2.  Effect of long-term axial spinal unloading on vertebral body height in adult thoracolumbar spine.

Authors:  Hamed Reihani Kermani; Zeynab Soroush
Journal:  Eur Spine J       Date:  2008-04-18       Impact factor: 3.134

3.  A method for quantitative measurement of lumbar intervertebral disc structures: an intra- and inter-rater agreement and reliability study.

Authors:  Andreas Tunset; Per Kjaer; Shadi Samir Chreiteh; Tue Secher Jensen
Journal:  Chiropr Man Therap       Date:  2013-08-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.