OBJECTIVE: To study the reliability of gait analysis data obtained using the Calibrated Anatomical System Technique (CAST) protocol and to verify the suitability and repeatability of the extraction of a number of parameters from the waveforms obtained. DESIGN: The experimental protocol and the parametric analysis technique were applied on a population of able-bodied subjects. BACKGROUND: The clinical interpretation process of gait data still needs a more accurate analysis of the reliability and repeatability of the measurements and a suitable procedure for data reduction useful for data comparison. METHODS: Gait analysis was performed in 20 able-bodied subjects using a stereophotogrammetric system and a forceplate. 124 parameters relative to time-distance, kinematic and kinetic variables were calculated by means of an automatic procedure and statistically analysed. RESULTS: Most of the parameters were found to be normally distributed with relatively small range of variation. Few of them showed poor repeatability, mostly due to the experimental inaccuracies introduced. Correlation of several gait parameters with age, sex, and speed of progression was also identified.
OBJECTIVE: To study the reliability of gait analysis data obtained using the Calibrated Anatomical System Technique (CAST) protocol and to verify the suitability and repeatability of the extraction of a number of parameters from the waveforms obtained. DESIGN: The experimental protocol and the parametric analysis technique were applied on a population of able-bodied subjects. BACKGROUND: The clinical interpretation process of gait data still needs a more accurate analysis of the reliability and repeatability of the measurements and a suitable procedure for data reduction useful for data comparison. METHODS: Gait analysis was performed in 20 able-bodied subjects using a stereophotogrammetric system and a forceplate. 124 parameters relative to time-distance, kinematic and kinetic variables were calculated by means of an automatic procedure and statistically analysed. RESULTS: Most of the parameters were found to be normally distributed with relatively small range of variation. Few of them showed poor repeatability, mostly due to the experimental inaccuracies introduced. Correlation of several gait parameters with age, sex, and speed of progression was also identified.
Authors: Andrea Giovanni Cutti; Alberto Ferrari; Pietro Garofalo; Michele Raggi; Angelo Cappello; Adriano Ferrari Journal: Med Biol Eng Comput Date: 2009-11-13 Impact factor: 2.602
Authors: Alberto Ferrari; Andrea Giovanni Cutti; Pietro Garofalo; Michele Raggi; Monique Heijboer; Angelo Cappello; Angelo Davalli Journal: Med Biol Eng Comput Date: 2009-11-13 Impact factor: 2.602
Authors: Maria Grazia Benedetti; Yusuke Okita; Elena Recubini; Elisabetta Mariani; Alberto Leardini; Marco Manfrini Journal: Clin Orthop Relat Res Date: 2016-01-11 Impact factor: 4.176
Authors: Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi Journal: Biomed Eng Online Date: 2017-08-18 Impact factor: 2.819