Literature DB >> 11415656

The static and dynamic behaviour of tibial fractures due to unlocking external fixators.

T N Gardner1, J R W Hardy, M Evans, J B Richardson, J Kenwright.   

Abstract

OBJECTIVE: To determine how the mechanical environment of a tibial fracture is influenced by unlocking an external fixator frame.
DESIGN: A clinical study examined 10 consecutive patients fixed with the Orthofix DAF.
BACKGROUND: It has been claimed that the healing of diaphyseal tibial fractures is assisted by unlocking external fixators to allow free axial movement, but the influence on the mechanical environment at the fracture has not been established.
METHODS: A transducer attached to bone screws measured dynamic interfragmentary displacement during walking both before and immediately after unlocking the fixator at 6 weeks in 10 subjects. Four subjects were monitored over the first hour after unlocking to measure interfragmentary gap shortening.
RESULTS: Mean peak amplitudes of cyclical axial and angular displacement before unlocking were 0.46 mm (SD 0.27) and 0.37 degrees (SD 0.30), and after were 0.42 mm (SD 0.19) and 0.34 degrees (SD 0.28). Mean peak torsional and transverse shear displacements were 0.21 degrees (SD 0.11) and 0.30 mm (SD 0.17) before unlocking, and after were 0.42 degrees (SD 0.39) and 0.51 mm (SD 0.60). Gaps shortened permanently by unrecoverable axial translations of between 0.2 and 1.4 mm; the mean was 0.69 mm.
CONCLUSIONS: Unlocking was found more often to reduce both axial and angular motion, but to increase shear. Overall, this may reduce maximum longitudinal strains in the external callus. The reduced motion may arise from gap shortening.

Entities:  

Year:  1996        PMID: 11415656     DOI: 10.1016/s0268-0033(96)00038-1

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  Correlation of shear to compression for progressive fracture obliquity.

Authors:  David W Lowenberg; Sean Nork; Frederick M Abruzzo
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

2.  Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail.

Authors:  Yi Zhu; Severin Meili; Changqing Zhang; Congfeng Luo; Bing-fang Zeng
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-09-01       Impact factor: 2.953

3.  Fatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study.

Authors:  Erik Hasenboehler; Wade R Smith; Laurence Laudicina; Giby C Philips; Philip F Stahel; Steven J Morgan
Journal:  J Orthop Surg Res       Date:  2006-12-11       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.