Literature DB >> 11415635

Direct measurement of hoop strains in the intact and torn human medial meniscus.

R Spencer Jones1, G C R Keene, D J A Learmonth, D Bickerstaff, N S Nawana, J J Costi, M J Pearcy.   

Abstract

OBJECTIVE: To measure the circumferential or hoop strains generated in the medial meniscus during loading of the knee joint and to examine the effect of longitudinal and radial tears in the meniscus on these strain values.
DESIGN: An in vitro investigation measuring the circumferential strains in the medial menisci of cadaveric human knees as they were loaded in a materials testing machine.
BACKGROUND: The menisci transmit approximately 50% of the load through the knee, the rest being transmitted by direct contact of the articular cartilage. Damage to the menisci will alter the pattern of load transmission as will meniscectomy. This study examined the changes in the mechanics of the meniscus in situ as a result of simulated tears to assess the effect of its load carrying capacity and the implications of surgery to remove part or all of a damaged meniscus.
METHODS: Nineteen human cadaveric knees were tested. Windows were made in the joint capsule and strain gauges inserted into the anterior, middle and posterior sections of the medial meniscus. The knees were then loaded to three times body weight at speeds of 50 and 500 mm/min, with the knee joint at 0 degrees and 30 degrees of flexion. The tests were repeated following the creation of a longitudinal or a radial tear in the meniscus.
RESULTS: The intact menisci showed significantly less strain in the posterior section compared to the anterior and middle sections (P < 0.003, with strains of 1.54%, 2.86% and 2.65% respectively). With a longitudinal tear this pattern changed with strains decreasing anteriorly and increasing posteriorly. There were also significant differences at different angles of knee joint flexion not seen in the intact meniscus. 50% radial tears reduced the strains anteriorly whilst a complete radial tear completely defunctioned the meniscus.
CONCLUSIONS: This study has shown that there are significantly different hoop strains produced in different sections of the medial meniscus under load and the patterns of strain distribution are disturbed by meniscal tears. RELEVANCE: These results provide important data for mathematical models which must include non-uniform behaviour. They also have implications for the surgical management of torn menisci. Undamaged portions should be preserved and the integrity of the circumferential fibres maintained to ensure the menisci retain a load bearing capability.

Entities:  

Year:  1996        PMID: 11415635     DOI: 10.1016/0268-0033(96)00003-4

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  51 in total

1.  Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

Authors:  Jaremy J Creechley; Madison E Krentz; Trevor J Lujan
Journal:  J Mech Behav Biomed Mater       Date:  2016-12-27

2.  Polyurethane-based cell-free scaffold for the treatment of painful partial meniscus loss.

Authors:  G Filardo; E Kon; F Perdisa; A Sessa; A Di Martino; M Busacca; S Zaffagnini; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-09       Impact factor: 4.342

3.  Macro- to microscale strain transfer in fibrous tissues is heterogeneous and tissue-specific.

Authors:  Woojin M Han; Su-Jin Heo; Tristan P Driscoll; Lachlan J Smith; Robert L Mauck; Dawn M Elliott
Journal:  Biophys J       Date:  2013-08-06       Impact factor: 4.033

4.  Dynamic tensile loading improves the functional properties of mesenchymal stem cell-laden nanofiber-based fibrocartilage.

Authors:  Brendon M Baker; Roshan P Shah; Alice H Huang; Robert L Mauck
Journal:  Tissue Eng Part A       Date:  2011-03-03       Impact factor: 3.845

5.  Knee Menisci.

Authors:  James Kevin Bryceland; Andrew John Powell; Thomas Nunn
Journal:  Cartilage       Date:  2016-07-07       Impact factor: 4.634

6.  Mountain ultramarathon results in temporary meniscus extrusion in healthy athletes.

Authors:  Theresa Diermeier; Knut Beitzel; Laura Bachmann; Wolf Petersen; Katrin Esefeld; Klaus Wörtler; Andreas B Imhoff; Andrea Achtnich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-11-21       Impact factor: 4.342

7.  Pullout failure strength of the posterior horn of the medial meniscus with root ligament tear.

Authors:  Young-Mo Kim; Yong-Bum Joo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-17       Impact factor: 4.342

8.  The Relationship between Meniscal Tears and Meniscal Position.

Authors:  Deborah M Allen; Ling Li; Michel D Crema; Monica D Marra; Ali Guermazi; Brad T Wyman; Marie-Pierre Hellio Le Graverand; Martin Englund; Kenneth D Brandt; David J Hunter
Journal:  Ther Adv Musculoskelet Dis       Date:  2010-12       Impact factor: 5.346

9.  Regional variation in T1ρ and T2 times in osteoarthritic human menisci: correlation with mechanical properties and matrix composition.

Authors:  M Son; S B Goodman; W Chen; B A Hargreaves; G E Gold; M E Levenston
Journal:  Osteoarthritis Cartilage       Date:  2013-03-14       Impact factor: 6.576

10.  Biodegradable polyurethane meniscal scaffold for isolated partial lesions or as combined procedure for knees with multiple comorbidities: clinical results at 2 years.

Authors:  Elizaveta Kon; Giuseppe Filardo; Stefano Zaffagnini; Alessandro Di Martino; Berardo Di Matteo; Giulio Maria Marcheggiani Muccioli; Maurizio Busacca; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-06       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.