Literature DB >> 11413067

A force platform for large human displacements.

P Desjardins1, M Gagnon.   

Abstract

This paper provides details of a force platform assembly suitable for measuring the magnitude, position and direction of ground reaction forces for manual handling tasks involving several footsteps in any horizontal direction. An approach to increase the natural frequency with the use of a vibration absorber is used; this frequency was found to be 41+/-2 Hz. The results show a maximum error of 22 N (2% of the full scale output) when a person performs repetitive movements from a squat position to a full extension and back to the squat position. Static tests show the maximal errors to be, vertically, 1.5% of the full scale output (1818+/-33 N), and horizontally, 4.9% of the full scale output (1177+/-6 N).

Entities:  

Mesh:

Year:  2001        PMID: 11413067     DOI: 10.1016/s1350-4533(01)00028-5

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  A chair with a platform setup to measure the forces under each thigh when sitting, rising from a chair and sitting down.

Authors:  S Nadeau; P Desjardins; A Brière; G Roy; D Gravel
Journal:  Med Biol Eng Comput       Date:  2008-01-09       Impact factor: 2.602

2.  Inertial Motion Capture-Based Estimation of L5/S1 Moments during Manual Materials Handling.

Authors:  Antoine Muller; Hakim Mecheri; Philippe Corbeil; André Plamondon; Xavier Robert-Lachaine
Journal:  Sensors (Basel)       Date:  2022-08-26       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.