Literature DB >> 11411141

Ambient air quality at the site of a former manufactured gas plant.

M J Collins1, P L Williams, D L MacIntosh.   

Abstract

Prior to the 1950's, manufactured gas was commercially produced from the pyrolysis of coal, coke, and oil at facilities that are termed manufactured gas plants (MGPs). The constituents of residual coal tar present on many MGP sites are an environmental health concern because of their toxicity and the possibility for their off-site migration via water and air. Atmospheric concentrations of five volatile organic compounds (VOCs, e.g., benzene), sixteen polycyclic aromatic hydrocarbons (PAHs, e.g., naphthalene) and particulate matter less than 10 microns in aerodynamic diameter (PM10) were measured at the site of a former MGP. Air samples were obtained before, during, and after excavation of subterranean coal tar at the site. The results of this investigation indicate that subterranean coal tar was not a primary source of VOCs and PAHs in the local atmosphere before or after remediation of the site. However, excavation, treatment, blending, and transfer of the coal tar during remediation generated concentrations of selected aromatic and semi-volatile organic compounds that were substantially greater than typical ambient levels. In addition, these data suggest that blending and mixing of coal tars could lead to exceedance of the U.S. National Ambient Air Quality Standard for PM10, although additional research is required to fully evaluate this possibility. Nuisance odors associated with the site remediation were likely the result of naphthalene and possibly isomers of xylene. Air pollutant concentrations measured adjacent to the excavation area and at the site perimeter during remediation activities were less than the relevant occupational and environmental exposure limits.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11411141     DOI: 10.1023/a:1010747225479

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  7 in total

1.  Air quality and pediatric emergency room visits for asthma in Atlanta, Georgia, USA.

Authors:  P E Tolbert; J A Mulholland; D L MacIntosh; F Xu; D Daniels; O J Devine; B P Carlin; M Klein; J Dorley; A J Butler; D F Nordenberg; H Frumkin; P B Ryan; M C White
Journal:  Am J Epidemiol       Date:  2000-04-15       Impact factor: 4.897

2.  Polycyclic aromatic hydrocarbons and polychlorinated biphenyls in air at an urban and a rural site near lake michigan.

Authors:  W E Cotham; T F Bidleman
Journal:  Environ Sci Technol       Date:  1995-11       Impact factor: 9.028

3.  Low flow rate sharp cut impactors for indoor air sampling: design and calibration.

Authors:  V A Marple; K L Rubow; W Turner; J D Spengler
Journal:  JAPCA       Date:  1987-11

4.  Odor thresholds and irritation levels of several chemical substances: a review.

Authors:  J H Ruth
Journal:  Am Ind Hyg Assoc J       Date:  1986-03

Review 5.  Environmental exposure to benzene: an update.

Authors:  L Wallace
Journal:  Environ Health Perspect       Date:  1996-12       Impact factor: 9.031

6.  The EPC approach to estimating safety from exposure to environmental chemicals.

Authors:  C A Williams; H D Jones; R W Freeman; M J Wernke; P L Williams; S M Roberts; R C James
Journal:  Regul Toxicol Pharmacol       Date:  1994-12       Impact factor: 3.271

7.  The metropolitan acid aerosol characterization study: results from the summer 1994 Washington, D.C. field study.

Authors:  H H Suh; Y Nishioka; G A Allen; P Koutrakis; R M Burton
Journal:  Environ Health Perspect       Date:  1997-08       Impact factor: 9.031

  7 in total
  3 in total

1.  Air quality status of an open pit mining area in India.

Authors:  S K Chaulya
Journal:  Environ Monit Assess       Date:  2005-06       Impact factor: 2.513

Review 2.  Naphthalene--an environmental and occupational toxicant.

Authors:  Ralf Preuss; Jürgen Angerer; Hans Drexler
Journal:  Int Arch Occup Environ Health       Date:  2003-08-15       Impact factor: 3.015

Review 3.  A critical review of naphthalene sources and exposures relevant to indoor and outdoor air.

Authors:  Chunrong Jia; Stuart Batterman
Journal:  Int J Environ Res Public Health       Date:  2010-07-20       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.