Correction factors in skin temperature measurement.

Z Jirak, M Jokl, J Stverák, R Pechlát.   

Abstract

In 14 persons the skin temperature has been measured by means of thermistor thermometer. The influence of the shape of the probe and the pressure exerted on the resulting value of the skin temperature has been proved. In 10 additional men the relation of the temperature difference (deltaT) to the exerted pressure (P) was determined, the regression equations were derived for relation deltaT/P, and the correlation coefficients for recalculation of the temperatures measured by thermistor thermometer with the pressure exerted 20 g to values determined by thermovision. The skin temperature values determined by thermography were used in 24 formulas (3-16 points) for calculation of mean skin temperature. The differences of the means in determining the optimal method (16 points) were evaluated by the t-test and by the percentage expression of aggrement for criteria plus or minus 0.1, plus or minus 0.2, plus or minus 0.5, and plus or minus 0.1 degrees C. For precise laboratory work 10 points of measurement are recommended; for measurement in the field 6 points of measurement are enough. Orientational measurement can be performed very well by means of Ramanathan method (4 points).

Entities:  

Mesh:

Year:  1975        PMID: 1141109     DOI: 10.1152/jappl.1975.38.4.752

Source DB:  PubMed          Journal:  J Appl Physiol        ISSN: 0021-8987            Impact factor:   3.531


  4 in total

1.  Effect of ambient temperature and attachment method on surface temperature measurements.

Authors:  Agnes Psikuta; Reto Niedermann; René M Rossi
Journal:  Int J Biometeorol       Date:  2013-05-19       Impact factor: 3.787

Review 2.  Clothing and exercise. I: Biophysics of heat transfer between the individual, clothing and environment.

Authors:  D D Pascoe; L A Shanley; E W Smith
Journal:  Sports Med       Date:  1994-07       Impact factor: 11.136

Review 3.  Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values.

Authors:  Braid A MacRae; Simon Annaheim; Christina M Spengler; René M Rossi
Journal:  Front Physiol       Date:  2018-01-30       Impact factor: 4.566

4.  A Thermal Skin Model for Comparing Contact Skin Temperature Sensors and Assessing Measurement Errors.

Authors:  Braid A MacRae; Christina M Spengler; Agnes Psikuta; René M Rossi; Simon Annaheim
Journal:  Sensors (Basel)       Date:  2021-07-19       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.