Literature DB >> 11410973

Infection control procedures used in conjunction with computed dental radiography.

J S Hubar1, D M Gardiner.   

Abstract

Infection control guidelines for dental radiography have been modified since 1986, when the American Dental Association and the Centers for Disease Control and Prevention supported the concept of "universal blood and body fluid precautions." With the introduction of computed digital radiography, hardware manufacturers recommend that alternative infection control techniques are necessary to prevent potential damage to the digital x-ray sensors placed inside the patient's mouth. Thirty first-year dental hygiene students were asked to insert and remove a Schick CDR number 2 size intraoral digital x-ray sensor into modified Rinn XCP bitewing bite blocks and a modified Rinn Snap-a-ray five times with each of the recommended infection control covers. Reduced rates of cross contamination are possible if the plastic barrier envelope has an additional latex finger cot stretched over it and the x-ray sensor. Sole usage of a latex finger cot will result in a reduced incidence of contamination, but still not to acceptable levels. However, a plastic barrier envelope placed over the x-ray sensor and over the modified XCP bite block together or a covered sensor in a Snap-a-ray under normal conditions does not result in a perforation and is least likely to result in cross contamination.

Entities:  

Mesh:

Year:  2000        PMID: 11410973

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  6 in total

1.  Perforation rate of intraoral barriers for direct digital radiography.

Authors:  J-W Choi
Journal:  Dentomaxillofac Radiol       Date:  2014-11-20       Impact factor: 2.419

Review 2.  Cross-contamination and infection control in intraoral digital imaging: a comprehensive review.

Authors:  Birsay Gumru; Bilge Tarcin; Ender Idman
Journal:  Oral Radiol       Date:  2020-06-06       Impact factor: 1.852

3.  Antimicrobial efficiency of ethanol and 2-propanol alcohols used on contaminated storage phosphor plates and impact on durability of the plate.

Authors:  A Wenzel; F Kornum; Mr Knudsen; E Frandsen Lau
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

4.  Dental radiographic procedures during COVID-19 outbreak and normalization period: recommendations on infection control.

Authors:  Betul Ilhan; İbrahim Sevki Bayrakdar; Kaan Orhan
Journal:  Oral Radiol       Date:  2020-06-29       Impact factor: 1.852

5.  Comparing the Disinfecting Efficacies of Micro 10, Deconex, Alprocid and Microzid AF on the Microorganisms on Radiographic Equipments.

Authors:  Fatemeh Ezoddini Ardakani; Hengameh Zandi; Zahed Mohammadi; Jamshid Ayatollahi; Fatemeh Ayatollahi; Behnaz Behniafar
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-08-15

6.  Effect of enveloping and disinfection methods on artefact formation on enveloped PSP plate images.

Authors:  Umut Pamukcu; Hatice Tetik; Ilkay Peker; Ozge Karadag Atas; Zuhre Zafersoy Akarslan
Journal:  Oral Radiol       Date:  2022-01-22       Impact factor: 1.882

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.