Literature DB >> 11409005

Experimental methodologies and preliminary transfer factor data for estimation of dermal exposures to particles.

C E Rodes1, J R Newsome, R W Vanderpool, J T Antley, R G Lewis.   

Abstract

Developmental efforts and experimental data that focused on quantifying the transfer of particles on a mass basis from indoor surfaces to human skin are described. Methods that utilized a common fluorescein-tagged Arizona Test Dust (ATD) as a possible surrogate for housedust and a uniform surface dust deposition chamber to permit estimation of particle mass transfer for selected dust size fractions were developed. Particle transfers to both wet and dry skin were quantified for contact events with stainless steel, vinyl, and carpeted surfaces that had been pre-loaded with the tagged test dust. To better understand the representativeness of the test dust, a large housedust sample was collected and analyzed for particle size distribution by mass and several metals (Pb, Mn, Cd, Cr, and Ni). The real housedust sample was found to have multimodal size distributions (mg/g) for particle-phase metals. The fluorescein tagging provided surface coatings of 0.11-0.36 ng fluorescein per gram of dust. The predominant surface location of the fluorescein tag would best represent simulated mass transfers for contaminant species coating the surfaces of the particles. The computer-controlled surface deposition chamber provided acceptably uniform surface coatings with known particle loadings on the contact test panels. Significant findings for the dermal transfer factor data were: (a) only about 1/3 of the projected hand surface typically came in contact with the smooth test surfaces during a press; (b) the fraction of particles transferred to the skin decreased as the surface roughness increased, with carpeting transfer coefficients averaging only 1/10 those of stainless steel; (c) hand dampness significantly increased the particle mass transfer; (d) consecutive presses decreased the particle transfer by a factor of 3 as the skin surface became loaded, requiring approximately 100 presses to reach an equilibrium transfer rate; and (e) an increase in metals concentration with decreasing particle size, with levels at 25 microns typically two or more times higher than those at 100 microns--consistent with the earlier finding of Lewis et al. for the same sample for pesticides and polycyclic aromatic hydrocarbons (PAHs).

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11409005     DOI: 10.1038/sj.jea.7500150

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  8 in total

1.  Experimental estimation of migration and transfer of organic substances from consumer articles to cotton wipes: Evaluation of underlying mechanisms.

Authors:  Per Axel Clausen; Suzanne Spaan; Derk H Brouwer; Hans Marquart; Maaike le Feber; Roel Engel; Lieve Geerts; Keld Alstrup Jensen; Vivi Kofoed-Sørensen; Brian Hansen; Katleen De Brouwere
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-05-20       Impact factor: 5.563

2.  Developing Health-Based Pre-Planning Clearance Goals for Airport Remediation Following a Chemical Terrorist Attack: Decision Criteria for Multipathway Exposure Routes.

Authors:  Annetta Watson; Fredrick Dolislager; Linda Hall; Ellen Raber; Veronique D Hauschild; Adam H Love
Journal:  Hum Ecol Risk Assess       Date:  2011-02-12       Impact factor: 5.190

Review 3.  Exposure science: a view of the past and milestones for the future.

Authors:  Paul J Lioy
Journal:  Environ Health Perspect       Date:  2010-03-22       Impact factor: 9.031

4.  Comparison of techniques to reduce residential lead dust on carpet and upholstery: the new jersey assessment of cleaning techniques trial.

Authors:  Lih-Ming Yiin; George G Rhoads; David Q Rich; Junfeng Zhang; Zhipeng Bai; John L Adgate; Peter J Ashley; Paul J Lioy
Journal:  Environ Health Perspect       Date:  2002-12       Impact factor: 9.031

5.  Evaluation of Potential Exposure to Metals in Laundered Shop Towels.

Authors:  Leslie A Beyer; Grace Greenberg; Barbara D Beck
Journal:  Hum Ecol Risk Assess       Date:  2013-10-11       Impact factor: 5.190

6.  Evaluating a transfer gradient assumption in a fomite-mediated microbial transmission model using an experimental and Bayesian approach.

Authors:  Amanda M Wilson; Marco-Felipe King; Martín López-García; Mark H Weir; Jonathan D Sexton; Robert A Canales; Georgiana E Kostov; Timothy R Julian; Catherine J Noakes; Kelly A Reynolds
Journal:  J R Soc Interface       Date:  2020-06-24       Impact factor: 4.118

7.  Particle transfer and adherence to human skin compared with cotton glove and pre-moistened polyvinyl alcohol exposure sampling substrates.

Authors:  Aleksandr B Stefaniak; Eleanor E Wade; Robert B Lawrence; Elizabeth D Arnold; M Abbas Virji
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2021-03-15       Impact factor: 2.269

8.  Early detection of viable Francisella tularensis in environmental matrices by culture-based PCR.

Authors:  Helen Y Buse; Brian J Morris; Eugene W Rice
Journal:  BMC Microbiol       Date:  2020-03-25       Impact factor: 3.605

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.