Literature DB >> 11408463

Ambulatory estimates of maximal aerobic power from foot -ground contact times and heart rates in running humans.

P G Weyand1, M Kelly, T Blackadar, J C Darley, S R Oliver, N E Ohlenbusch, S W Joffe, R W Hoyt.   

Abstract

Seeking to develop a simple ambulatory test of maximal aerobic power (VO(2 max)), we hypothesized that the ratio of inverse foot-ground contact time (1/t(c)) to heart rate (HR) during steady-speed running would accurately predict VO(2 max). Given the direct relationship between 1/t(c) and mass-specific O(2) uptake during running, the ratio 1/t(c). HR should reflect mass-specific O(2) pulse and, in turn, aerobic power. We divided 36 volunteers into matched experimental and validation groups. VO(2 max) was determined by a treadmill test to volitional fatigue. Ambulatory monitors on the shoe and chest recorded foot-ground contact time (t(c)) and steady-state HR, respectively, at a series of submaximal running speeds. In the experimental group, aerobic fitness index (1/t(c). HR) was nearly constant across running speed and correlated with VO(2 max) (r = 0.90). The regression equation derived from data from the experimental group predicted VO(2 max) from the 1/t(c). HR values in the validation group within 8.3% and 4.7 ml O(2) x kg(-1) x min(-1) (r = 0.84) of measured values. We conclude that simultaneous measurements of foot-ground constant times and heart rates during level running at a freely chosen constant speed can provide accurate estimates of maximal aerobic power.

Entities:  

Mesh:

Year:  2001        PMID: 11408463     DOI: 10.1152/jappl.2001.91.1.451

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  13 in total

1.  Accuracy of uniaxial accelerometer in chronic obstructive pulmonary disease.

Authors:  Marilyn L Moy; Eric Garshick; Kirby R Matthess; Robert Lew; John J Reilly
Journal:  J Rehabil Res Dev       Date:  2008

Review 2.  Estimation of maximal oxygen uptake via submaximal exercise testing in sports, clinical, and home settings.

Authors:  Francesco Sartor; Gianluca Vernillo; Helma M de Morree; Alberto G Bonomi; Antonio La Torre; Hans-Peter Kubis; Arsenio Veicsteinas
Journal:  Sports Med       Date:  2013-09       Impact factor: 11.136

3.  Data fusion of body-worn accelerometers and heart rate to predict VO2max during submaximal running.

Authors:  Arne De Brabandere; Tim Op De Beéck; Kurt H Schütte; Wannes Meert; Benedicte Vanwanseele; Jesse Davis
Journal:  PLoS One       Date:  2018-06-29       Impact factor: 3.240

Review 4.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

5.  Free-living physical activity in COPD: assessment with accelerometer and activity checklist.

Authors:  Marilyn L Moy; Kirby Matthess; Kelly Stolzmann; John Reilly; Eric Garshick
Journal:  J Rehabil Res Dev       Date:  2009

Review 6.  Step Counting: A Review of Measurement Considerations and Health-Related Applications.

Authors:  David R Bassett; Lindsay P Toth; Samuel R LaMunion; Scott E Crouter
Journal:  Sports Med       Date:  2017-07       Impact factor: 11.136

7.  Running Speed Can Be Predicted from Foot Contact Time during Outdoor over Ground Running.

Authors:  Cornelis J de Ruiter; Ben van Oeveren; Agnieta Francke; Patrick Zijlstra; Jaap H van Dieen
Journal:  PLoS One       Date:  2016-09-20       Impact factor: 3.240

8.  A universal approach to determine footfall timings from kinematics of a single foot marker in hoofed animals.

Authors:  Sandra D Starke; Hilary M Clayton
Journal:  PeerJ       Date:  2015-03-26       Impact factor: 2.984

9.  Unobtrusive Estimation of Cardiorespiratory Fitness with Daily Activity in Healthy Young Men.

Authors:  Joong Woo Ahn; Se Hee Hwang; Chiyul Yoon; Joonnyong Lee; Hee Chan Kim; Hyung Jin Yoon
Journal:  J Korean Med Sci       Date:  2017-12       Impact factor: 2.153

10.  A "Wearable" Test for Maximum Aerobic Power: Real-Time Analysis of a 60-m Sprint Performance and Heart Rate Off-Kinetics.

Authors:  Jorge L Storniolo; Gaspare Pavei; Alberto E Minetti
Journal:  Front Physiol       Date:  2017-11-01       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.