Effect of ventilation-perfusion inhomogeneity and N(2)O on oxygenation: physiological modeling of gas exchange.

P J Peyton1, G J Robinson, B Thompson.   

Abstract

Ventilation-perfusion (VA/Q) inhomogeneity was modeled to measure its effect on arterial oxygenation during maintenance-phase anesthesia involving an inspired mixture of 30% O(2) and either N(2)O or N(2). A multialveolar compartment computer model was constructed based on a log normal distribution of VA/Q inhomogeneity. Increasing the log SD of the distribution of blood flow from 0 to 1.75 produced a progressive fall in arterial PO(2) (Pa(O(2))). The fall was less steep in the presence of N(2)O than when N(2) was present instead. This was due mainly to the concentrating effect of N(2)O uptake on alveolar PO(2) in moderately low VA/Q compartments. The improvement in Pa(O(2)) when N(2)O was present instead of N(2) was greatest when the degree of VA/Q inhomogeneity was in the range typically seen in anesthetized patients. Models based on distributions of expired and inspired alveolar ventilation give quantitatively different results for Pa(O(2)). In the presence of VA/Q inhomogeneity, second-gas and concentrating effects may have clinically significant effects on arterial oxygenation even at "steady-state" levels of N(2)O uptake.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11408408     DOI: 10.1152/jappl.2001.91.1.17

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  6 in total

1.  Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography.

Authors:  Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2012-02-18       Impact factor: 2.502

2.  Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO(2) Fick method.

Authors:  Philip J Peyton; Daniel Thompson; Paul Junor
Journal:  J Clin Monit Comput       Date:  2008-07-12       Impact factor: 2.502

3.  Effect of net gas volume changes on alveolar and arterial gas partial pressures in the presence of ventilation-perfusion mismatch.

Authors:  Ben Korman; Ranjan K Dash; Philip J Peyton
Journal:  J Appl Physiol (1985)       Date:  2018-12-06

4.  Performance of a second generation pulmonary capnotracking system for continuous monitoring of cardiac output.

Authors:  Philip J Peyton; Monique Kozub
Journal:  J Clin Monit Comput       Date:  2018-02-08       Impact factor: 2.502

5.  Can Mathematical Modeling Explain the Measured Magnitude of the Second Gas Effect?

Authors:  Ben Korman; Ranjan K Dash; Philip J Peyton
Journal:  Anesthesiology       Date:  2018-06       Impact factor: 7.892

6.  Between prediction, education, and quality control: simulation models in critical care.

Authors:  Herwig Gerlach; Susanne Toussaint
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.