Literature DB >> 11407800

Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults.

B Gurney1, C Mermier, R Robergs, A Gibson, D Rivero.   

Abstract

BACKGROUND: The amount of limb-length discrepancy necessary to adversely affect gait parameters in older adults is unknown, with information being largely anecdotal. This investigation was conducted to determine the effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults.
METHODS: Forty-four men and women ranging in age from fifty-five to eighty-six years with no evidence of limb-length discrepancy of >1 cm participated in the study. Subjects walked on a treadmill at a self-selected normal walking pace with artificial limb-length discrepancies of 0, 2, 3, and 4 cm applied in a randomly selected order. Indirect calorimetry was used to measure oxygen consumption and minute ventilation. Electromyography was used to measure muscle activity of the right and left quadriceps femoris, plantar flexors, gluteus maximus, and gluteus medius. Heart rate, the rating of perceived exertion, and frequency of gait compensation patterns were also measured.
RESULTS: There was a significant increase in oxygen consumption and the rating of perceived exertion with 2, 3, and 4-cm artificial limb-length discrepancies; a significant increase in heart rate, minute ventilation, and quadriceps activity in the longer limb with 3 and 4-cm artificial limb-length discrepancies; and a significant increase in plantar flexor activity in the shorter limb with a 4-cm artificial limb-length discrepancy compared with the same parameters with no artificial limb-length discrepancy.
CONCLUSIONS: Both oxygen consumption and the rating of perceived exertion were greater with a 2-cm artificial limb-length discrepancy than they were with no artificial limb-length discrepancy. There appears to be a breakpoint between 2 and 3 cm of artificial limb-length discrepancy in older adults with regard to the effects on most other physiological parameters. A 3-cm artificial limb-length discrepancy is likely to induce significant quadriceps fatigue in the longer limb. Elderly patients with substantial pulmonary, cardiac, or neuromuscular disease may have difficulty walking with a limb-length discrepancy as small as 2 cm.

Entities:  

Mesh:

Year:  2001        PMID: 11407800     DOI: 10.2106/00004623-200106000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  46 in total

1.  Structural allograft and primary press-fit cup for severe acetabular deficiency. A minimum 6-year follow-up study.

Authors:  F Traina; F Giardina; M De Clerico; A Toni
Journal:  Int Orthop       Date:  2005-04-05       Impact factor: 3.075

2.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

3.  A multimodal approach in total hip arthroplasty preoperative templating.

Authors:  Massimiliano Marcucci; Pier Francesco Indelli; Leonardo Latella; Paolo Poli; Devin King
Journal:  Skeletal Radiol       Date:  2013-07-05       Impact factor: 2.199

4.  The relation between mild leg-length inequality and able-bodied gait asymmetry.

Authors:  Matthew K Seeley; Brian R Umberger; Jody L Clasey; Robert Shapiro
Journal:  J Sports Sci Med       Date:  2010-12-01       Impact factor: 2.988

5.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

6.  A comparison of two different navigated hip replacement techniques on leg length discrepancy.

Authors:  T N Jennison; P Craig; Edward D Davis
Journal:  J Orthop       Date:  2018-02-21

7.  A new method for intraoperative assessment of leg length, sizing and placement of the components in total hip replacement.

Authors:  Ioannis P Stathopoulos; Nicolaos Andrianopoulos; Dimitrios Paschaloglou; Kalliopi Lampropoulou-Adamidou; Maria Spetsaki; Ioannis K Tsarouchas
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-02

8.  Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA.

Authors:  Markus Weber; Michael Woerner; Robert Springorum; Ernst Sendtner; Alexander Hapfelmeier; Joachim Grifka; Tobias Renkawitz
Journal:  Clin Orthop Relat Res       Date:  2014-06-26       Impact factor: 4.176

9.  To what extent does leg length discrepancy impair motor activity in patients after total hip arthroplasty?

Authors:  Maria Grazia Benedetti; Fabio Catani; Emanuela Benedetti; Lisa Berti; Annalisa Di Gioia; Sandro Giannini
Journal:  Int Orthop       Date:  2009-09-18       Impact factor: 3.075

10.  Arthrodesis After Infected Revision TKA: Retrospective Comparison of Intramedullary Nailing and External Fixation.

Authors:  Francesco Iacono; Iacono Francesco; Giovanni Francesco Raspugli; Raspugli Giovanni Francesco; Danilo Bruni; Bruni Danilo; Mirco Lo Presti; Lo Presti Mirco; Bharat Sharma; Sharma Bharat; Ibrahim Akkawi; Akkawi Ibrahim; Maurilio Marcacci; Marcacci Maurilio
Journal:  HSS J       Date:  2013-08-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.