Literature DB >> 11404848

High-speed liquid chromatography/tandem mass spectrometry using a monolithic column for high-throughput bioanalysis.

J T Wu1, H Zeng, Y Deng, S E Unger.   

Abstract

With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11404848     DOI: 10.1002/rcm.348

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

Review 1.  Tandem mass spectrometry for characterization of covalent adducts of DNA with anticancer therapeutics.

Authors:  Catherine Silvestri; Jennifer S Brodbelt
Journal:  Mass Spectrom Rev       Date:  2012-11-13       Impact factor: 10.946

2.  Ultrafast liquid chromatography-tandem mass spectrometry determination of donepezil in human plasma: application to a bioequivalence study.

Authors:  Yan-Wen Huang; Li Ding; Yuan-Ming Chen; Wei-Chen Lin; Fei Lin; Yunsheng Hsieh
Journal:  Transl Clin Pharmacol       Date:  2022-02-24
  2 in total