A blood pressure sensor for long-term implantation.

E Bullister1, S Reich, P D'Entremont, N Silverman, J Sluetz.   

Abstract

An implantable flow-through blood pressure sensor prototype has been developed for use with an implantable left ventricular assist device (LVAD). This sensor incorporates a flat pressure-sensing diaphragm that is designed to be integral with the wall of a titanium tube that may be placed in the inlet or the outlet flow path of any LVAD. The interior tube flow geometry is transitioned from a round to a D-shape such that flow separation is eliminated. Bench testing of 3 sensors was performed to characterize the sensor. The worst-case results showed a maximum nonlinearity of 0.64 mm Hg, a maximum hysteresis of 0.87 mm Hg, and a maximum nonrepeatability of 0.87 mm Hg. Long-term drift studies of 2 sensors at 193 days and 112 days resulted in a projected annual drift rate of 1.4 and 2.0 mm Hg, respectively. The APEX pressure sensors were evaluated in 5 ventricular assist acute calf experiments in which the sensor outputs were compared with Millar pressure catheter sensors. Pressure output comparisons showed similar pressure tracings. No visible evidence of thrombus formation was found on the APEX sensor compared with thrombus formation found on the Millar catheter at the entrance to the flow path. Tests demonstrated that the blood pressure sensor can accurately measure blood pressure and indicate that it has long-term stability.

Entities:  

Mesh:

Year:  2001        PMID: 11403667     DOI: 10.1046/j.1525-1594.2001.025005376.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  5 in total

1.  Development of an inlet pressure sensor for control in a left ventricular assist device.

Authors:  Bryan Fritz; Joshua Cysyk; Ray Newswanger; William Weiss; Gerson Rosenberg
Journal:  ASAIO J       Date:  2010 May-Jun       Impact factor: 2.872

2.  Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device.

Authors:  Wei Shi; Itsuro Saito; Takashi Isoyama; Hidemoto Nakagawa; Yusuke Inoue; Toshiya Ono; Akimasa Kouno; Kou Imachi; Yusuke Abe
Journal:  J Artif Organs       Date:  2011-03-05       Impact factor: 1.731

3.  Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation.

Authors:  Mahdi Mansouri; Shaun D Gregory; Robert F Salamonsen; Nigel H Lovell; Michael C Stevens; Jo P Pauls; Rini Akmeliawati; Einly Lim
Journal:  PLoS One       Date:  2017-02-17       Impact factor: 3.240

4.  An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device.

Authors:  Luigi Brancato; Grim Keulemans; Tom Verbelen; Bart Meyns; Robert Puers
Journal:  Micromachines (Basel)       Date:  2016-08-08       Impact factor: 2.891

5.  In Silico and in Vitro Conductivity Models of the Left Heart Ventricle.

Authors:  Leonie Korn; Simon Lyra; Daniel Rüschen; Dmitry Telyshev; Steffen Leonhardt; Marian Walter
Journal:  J Electr Bioimpedance       Date:  2020-08-26