Literature DB >> 11403196

Maximum-likelihood expectation-maximization reconstruction of sinograms with arbitrary noise distribution using NEC-transformations.

J Nuyts1, C Michel, P Dupont.   

Abstract

The maximum-likelihood (ML) expectation-maximization (EM) [ML-EM] algorithm is being widely used for image reconstruction in positron emission tomography. The algorithm is strictly valid if the data are Poisson distributed. However, it is also often applied to processed sinograms that do not meet this requirement. This may sometimes lead to suboptimal results: streak artifacts appear and the algorithm converges toward a lower likelihood value. As a remedy, we propose two simple pixel-by-pixel methods [noise equivalent counts (NEC)-scaling and NEC-shifting] in order to transform arbitrary sinogram noise into noise which is approximately Poisson distributed (the first and second moments of the distribution match those of the Poisson distribution). The convergence speed associated with both transformation methods is compared, and the NEC-scaling method is validated with both simulations and clinical data. These new methods extend the ML-EM algorithm to a general purpose nonnegative reconstruction algorithm.

Mesh:

Year:  2001        PMID: 11403196     DOI: 10.1109/42.925290

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Treatment response evaluation using 18F-FDOPA PET in patients with recurrent malignant glioma on bevacizumab therapy.

Authors:  Johannes Schwarzenberg; Johannes Czernin; Timothy F Cloughesy; Benjamin M Ellingson; Whitney B Pope; Tristan Grogan; David Elashoff; Cheri Geist; Daniel H S Silverman; Michael E Phelps; Wei Chen
Journal:  Clin Cancer Res       Date:  2014-03-31       Impact factor: 12.531

2.  Comparison of visual and semiquantitative analysis of 18F-FDOPA-PET/CT for recurrence detection in glioblastoma patients.

Authors:  Ken Herrmann; Johannes Czernin; Timothy Cloughesy; Albert Lai; Kelsey L Pomykala; Matthias R Benz; Andreas K Buck; Michael E Phelps; Wei Chen
Journal:  Neuro Oncol       Date:  2013-12-04       Impact factor: 12.300

3.  Rate of change in maximum 18F-FDOPA PET uptake and non-enhancing tumor volume predict malignant transformation and overall survival in low-grade gliomas.

Authors:  Talia C Oughourlian; Jingwen Yao; Jacob Schlossman; Catalina Raymond; Matthew Ji; Hiroyuki Tatekawa; Noriko Salamon; Whitney B Pope; Johannes Czernin; Phioanh L Nghiemphu; Albert Lai; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  J Neurooncol       Date:  2020-01-24       Impact factor: 4.130

4.  Technical Note: Emission expectation maximization look-alike algorithms for x-ray CT and other applications.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2018-07-02       Impact factor: 4.071

5.  ¹⁸F-FLT    and ¹⁸F-FDOPA PET kinetics in recurrent brain tumors.

Authors:  Mirwais Wardak; Christiaan Schiepers; Timothy F Cloughesy; Magnus Dahlbom; Michael E Phelps; Sung-Cheng Huang
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-07       Impact factor: 9.236

6.  Higher SNR PET image prediction using a deep learning model and MRI image.

Authors:  Chih-Chieh Liu; Jinyi Qi
Journal:  Phys Med Biol       Date:  2019-05-23       Impact factor: 3.609

7.  18F-FDOPA PET and MRI characteristics correlate with degree of malignancy and predict survival in treatment-naïve gliomas: a cross-sectional study.

Authors:  Chirag B Patel; Elisa Fazzari; Ararat Chakhoyan; Jingwen Yao; Catalina Raymond; Huytram Nguyen; Jasmine Manoukian; Nhung Nguyen; Whitney Pope; Timothy F Cloughesy; Phioanh L Nghiemphu; Johannes Czernin; Albert Lai; Benjamin M Ellingson
Journal:  J Neurooncol       Date:  2018-04-20       Impact factor: 4.130

8.  pH-weighted molecular imaging of gliomas using amine chemical exchange saturation transfer MRI.

Authors:  Robert J Harris; Timothy F Cloughesy; Linda M Liau; Robert M Prins; Joseph P Antonios; Debiao Li; William H Yong; Whitney B Pope; Albert Lai; Phioanh L Nghiemphu; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2015-06-24       Impact factor: 12.300

9.  Correlation of MRI-derived apparent diffusion coefficients in newly diagnosed gliomas with [18F]-fluoro-L-dopa PET: what are we really measuring with minimum ADC?

Authors:  S Rose; M Fay; P Thomas; P Bourgeat; N Dowson; O Salvado; Y Gal; A Coulthard; S Crozier
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-18       Impact factor: 3.825

10.  Multiparametric MR-PET measurements in hypermetabolic regions reflect differences in molecular status and tumor grade in treatment-naïve diffuse gliomas.

Authors:  Hiroyuki Tatekawa; Akifumi Hagiwara; Hiroyuki Uetani; Jingwen Yao; Talia C Oughourlian; Shadfar Bahri; Chencai Wang; Catalina Raymond; Albert Lai; Timothy F Cloughesy; Phioanh L Nghiemphu; Linda M Liau; Whitney B Pope; Noriko Salamon; Benjamin M Ellingson
Journal:  J Neurooncol       Date:  2020-09-14       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.