Modeling the vertical motion of a soft contact lens.

A Chauhan1, C J Radke.   

Abstract

PURPOSE: The motion of a soft contact lens in the up-down or vertical (inferior-superior) and in-out (anterior-posterior) directions drives mixing in the post lens tear film. Thus, it is important to obtain an accurate assessment of lens motion. The commonly used experimental technique to measure the vertical motion, video microscopy, only gauges motion during the interblink period. Since most of the eyelid force, which drives the motion, is exerted during the blink, it is reasonable to assume that the majority of the lens motion in the up-down direction takes place during the blink and is, therefore, hidden from view. Thus, experimentally measured values of vertical lens travel are currently underpredicted.
METHODS: In this paper, we use a simple mechanical force balance on the lens to predict its motion in the vertical direction. The forces included in our model are due to the upper and the lower eyelids, gravity, elasticity, and viscous stresses. We input the lens physical parameters, the various tear film thicknesses, and the upper eyelid velocity. Then we integrate a macroscopic force balance to obtain the lens vertical position as a function of time.
RESULTS: The proposed model predicts that the downward lens motion during a blink is about 2--3 times the downward motion during the interblink (centration).
CONCLUSIONS: The up-down motion observable during the interblink period is only a small fraction of the total lens vertical travel.

Mesh:

Year:  2001        PMID: 11402387     DOI: 10.1076/ceyr.22.2.102.5521

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  4 in total

Review 1.  Nanoparticles for the treatment of glaucoma-associated neuroinflammation.

Authors:  Lidawani Lambuk; Nurfatihah Azlyna Ahmad Suhaimi; Muhammad Zulfiqah Sadikan; Azliana Jusnida Ahmad Jafri; Suhana Ahmad; Nurul Alimah Abdul Nasir; Vuk Uskoković; Ramlah Kadir; Rohimah Mohamud
Journal:  Eye Vis (Lond)       Date:  2022-07-02

2.  Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography.

Authors:  Lele Cui; Ming Li; Meixiao Shen; Fan Lu; Jianhua Wang
Journal:  J Ophthalmol       Date:  2017-06-01       Impact factor: 1.909

3.  Effect of visual attention and horizontal vergence in three-dimensional space on occurrence of optokinetic nystagmus.

Authors:  Kei Kanari; Hirohiko Kaneko
Journal:  J Eye Mov Res       Date:  2019-02-28       Impact factor: 0.957

Review 4.  Unraveling the mechanobiology of cornea: From bench side to the clinic.

Authors:  Shu Yang; Jing Zhang; Youhua Tan; Yan Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-10-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.