Literature DB >> 11402291

Comparative dose measurements by spiral tomography for preimplant diagnosis: the Scanora machine versus the Cranex Tome radiography unit.

K Dula1, R Mini, P F van der Stelt, G C Sanderink, P Schneeberger, D Buser.   

Abstract

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine. Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11402291     DOI: 10.1067/moe.2001.113591

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  4 in total

1.  Influence of lead apron shielding on absorbed doses from panoramic radiography.

Authors:  D Rottke; L Grossekettler; K Sawada; P Poxleitner; D Schulze
Journal:  Dentomaxillofac Radiol       Date:  2013-10-30       Impact factor: 2.419

2.  Magnification rate of digital panoramic radiographs and its effectiveness for pre-operative assessment of dental implants.

Authors:  Y-K Kim; J-Y Park; S-G Kim; J-S Kim; J-D Kim
Journal:  Dentomaxillofac Radiol       Date:  2011-02       Impact factor: 2.419

3.  Cone-beam computed tomography evaluation of the pterygomaxillary fissure and pterygopalatine fossa using 3D rendering programs.

Authors:  Murat Icen; Kaan Orhan
Journal:  Surg Radiol Anat       Date:  2019-02-06       Impact factor: 1.246

4.  Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT.

Authors:  Dae-Kyo Jeong; Sang-Chul Lee; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2012-06-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.