Literature DB >> 11401074

The infant lung function model: a mechanical analogue to test infant lung function equipment.

U Frey1, B Reinmann, J Stocks.   

Abstract

To facilitate international multicentre studies and quality control of infant pulmonary function measurements, the European Respiratory Society-American Thoracic Society (ERS-ATS) working group for infant lung function testing aims to develop specifications for standardized infant lung function equipment and software. However, a standardized test device is also needed to test whether existing infant lung function equipment is able to meet these requirements. The authors have built a "mechanical model baby" consisting of a linear pump which can reproduce prerecorded tidal flow waveforms with a precision of 0.5% (full stroke), enabling the simulation of tidal and forced flow patterns. This linear pump can be connected to a series of copper lung volumes (range 50-300 mL) with known time constants, so that lung volumes can be reproduced with a precision of +/-1% at frequencies 10-120bpm. Five airflow resistors were built using sinter material. When assessed using flows 0-300 mL.s(-1) all resistors showed a quasilinear pressure/ flow relationship, with slopes 1.0-5.6 kPa.L(-1).s. These resistances could be reproduced with a precision of +/-2.5%. The infant lung model can also be used to assess frequency responses of infant lung function equipment, since the pump is capable of delivering low amplitude volumes up to 20 Hz in a pseudorandom noise manner. In summary, based on error estimations, this infant lung model is able to test whether or not infant lung function equipment meets the requirements suggested by the European Respiratory Society-American Thoracic Society standardization group, that is: flow measurements within +/-2.5%, volume and resistance measurements within +/-5%, frequency response: magnitude attenuation <+/-10% and phase shift <+/-3 degrees at 10 Hz.

Entities:  

Mesh:

Year:  2001        PMID: 11401074     DOI: 10.1183/09031936.01.17407550

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  3 in total

1.  Pulmonary functions before and after pediatric cardiac surgery.

Authors:  Hala Agha; Fatma El Heinady; Mona El Falaky; Alae Sobih
Journal:  Pediatr Cardiol       Date:  2013-10-30       Impact factor: 1.655

2.  Cohort profile: the Bern infant lung development cohort.

Authors:  Oliver Fuchs; Philipp Latzin; Claudia E Kuehni; Urs Frey
Journal:  Int J Epidemiol       Date:  2011-01-13       Impact factor: 7.196

3.  A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories.

Authors:  Bruno Demoulin; Iulia Ioan; Claude Duvivier; Claude Bonabel; Cyril Schweitzer; François Marchal; Silvia Demoulin-Alexikova
Journal:  Front Physiol       Date:  2018-10-09       Impact factor: 4.566

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.