Reproducibility of skin characterization with backscattered spectra (12--25 MHz) in healthy subjects.

C Fournier1, S L Bridal, G Berger, P Laugier.   

Abstract

Ultrasonic techniques were developed for quantitative in vivo analysis of skin composition based on measurements of apparent integrated backscatter (IBS) and its frequency dependence (n) between 12.5 and 25 MHz. Parameters were measured at five depths in healthy dermis of the midforearm of 29 volunteers (13 women, 16 men, 20 to 76 years old) on three different days. Reproducibility of measurements was evaluated (standardized coefficients of variation: 7% to 11% for IBS and 9% to 20% for n). Parameter values were significantly influenced by pressure of the ultrasonic probe on the skin, and both room and skin-surface temperatures were correlated to IBS measured in a single subject on 28 days. More precise control of these factors could further improve measurement reproducibility and sensitivity to skin composition. Significant (p < 0.05) differences of parameter values with respect to region of interest depth, age and gender of subjects were discussed in comparison with dermal composition and offer promise that these parameters could be used to characterize skin modifications.

Entities:  

Mesh:

Year:  2001        PMID: 11397524     DOI: 10.1016/s0301-5629(01)00344-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Improved visualization of high-intensity focused ultrasound lesions.

Authors:  Ronald H Silverman; Robert Muratore; Jeffrey A Ketterling; Jonathan Mamou; D Jackson Coleman; Ernest J Feleppa
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

2.  Frequency dependence of attenuation and backscatter coefficient of ex vivo human lymphedema dermis.

Authors:  Masaaki Omura; Kenji Yoshida; Shinsuke Akita; Tadashi Yamaguchi
Journal:  J Med Ultrason (2001)       Date:  2019-09-12       Impact factor: 1.314

3.  Quantified ultrasound elastography in the assessment of cutaneous carcinoma.

Authors:  Bahar Dasgeb; Michael A Morris; Darius Mehregan; Eliot L Siegel
Journal:  Br J Radiol       Date:  2015-08-13       Impact factor: 3.039

4.  Miniaturized Water-Jet Ultrasound Indentation System for Quantitative Assessment of Articular Cartilage Degeneration: A Validation Study.

Authors:  Yan-Ping Huang; Yong-Ping Zheng
Journal:  Biomed Res Int       Date:  2020-07-15       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.