Literature DB >> 11397029

All sealed endoleaks are not the same: a treatment strategy based on an ex-vivo analysis.

M Mehta1, T Ohki, F J Veith, E C Lipsitz.   

Abstract

PURPOSE: factors contributing to pressure transmission through thrombosed or sealed endoleaks have not been elucidated. The purpose of this investigation was to create an ex-vivo model that mimics patent and sealed endoleaks and that can quantitatively analyse the effects of length, diameter and thrombus on pressure transmission to the interior of the aneurysm sac.
METHODS: In the ex-vivo model, endoleak channels (ELCs) of various lengths (2 cm, 6 cm, 10 cm) and diameters (0.6 cm, 1.0 cm, 1.4 cm) were constructed using polytetrafluoroethylene (PTFE) grafts and attached to an artificial aneurysm sac. These ELCs were incorporated within a mock circulation made of rubber tubing connected to a pulsatile pump. Peak systolic pressure (PSP) was recorded in the aneurysm sac, distal to each ELC. Subsequently the ELCs were filled with human thrombus, and the pressure measurements repeated (n =5). Data was evaluated by regression analysis.
RESULTS: Peak systolic pressure in the artificial circulation was maintained at 150 mmHg. In the absence of thrombus pressure did not change across the ELC, regardless of its length or diameter. In the presence of organised thrombus, the pressure curves distal to the ELC were dampened, and the pressure reduction was directly proportional to the length and inversely proportional to the diameter of the ELC. Regression analysis indicated statistical significance.
CONCLUSION: In the absence of thrombosis, pressure transmitted via an ELC to the aneurysm sac is unchanged regardless of its length or diameter. All sealed endoleaks also transmit pressure. However, when an endoleak has thrombosed, pressure reduction is directly proportional to the length and inversely proportional to the diameter of its channel. This ex-vivo model suggests that Type 2 endoleaks with longer channels and smaller diameters would derive a greater benefit from adjunctive manoeuvres (coil embolisation) that hasten thrombosis. On the other hand, thrombosis of endoleaks with short and wide channels (e.g. Type 1) may not result in substantial pressure reduction within the aneurysm sac and a successful outcome. Copyright 2001 Harcourt Publishers Limited.

Entities:  

Mesh:

Year:  2001        PMID: 11397029     DOI: 10.1053/ejvs.2001.1349

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  2 in total

1.  Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience.

Authors:  T Ohki; F J Veith; P Shaw; E Lipsitz; W D Suggs; R A Wain; M Bade; M Mehta; N Cayne; J Cynamon; J Valldares; J McKay
Journal:  Ann Surg       Date:  2001-09       Impact factor: 12.969

Review 2.  Endotension: twenty years of a controversial term.

Authors:  Álvaro Torres-Blanco; Manuel Miralles-Hernández
Journal:  CVIR Endovasc       Date:  2021-06-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.