Abstract
An improved high-performance liquid chromatographic method has been developed to measure human plasma concentrations of the analgesic nonsteroidal anti-inflammatory drug ketorolac for use in pharmacokinetic studies. Samples were prepared for analysis by solid-phase extraction using Bond-Elut PH columns, with nearly complete recovery of both ketorolac and the internal standard tolmetin. The two compounds were separated on a Radial-Pak C18 column using a mobile phase consisting of water-acetonitrile-1.0 mol/l dibutylamine phosphate (pH 2.5) (30:20:1) and detected at a UV wavelength of 313 nm. Using only 250 microl of plasma, the standard curve was linear from 0.05 to 10.0 microg/ml.Entities:
Mesh:
Substances:
Year: 2001 PMID: 11393731 DOI: 10.1016/s0378-4347(01)00134-7