Literature DB >> 11393471

Monte Carlo-aided dosimetry of the Source Tech Medical Model STM1251 I-125 interstitial brachytherapy source.

A S Kirov1, J F Williamson.   

Abstract

We have used Monte Carlo photon transport simulations to calculate the dosimetric parameters of a new 125I seed, the Source Tech Medical Model STM125I source for interstitial brachytherapy. We followed the recommendations of the AAPM Task Group 43 and determined the following parameters: dose-rate constant, radial dose function, anisotropy function, anisotropy factor, and anisotropy constant. The recently (January 1999) revised National Institute of Standards and Technology I-125 standard for air-kerma strength calibration was taken into account as well as updated interaction cross-section data. The calculated dose-rate constant, when normalized to the simulated wide-angle, free-air chamber measurement of air-kerma strength, is 0.980 cGy h(-1) U(-1). The calculated radial dose function for the Model STM 1251 source is more penetrating than that of the model 6711 seed (by 18% at 5 cm distance), but agrees closely (within statistical errors) with that of the model 6702 seed up to distances of 10 cm. The STM125I source anisotropy functions indicate that its dose distribution is somewhat more anisotropic than that of the model 6702 and 6711 seeds at 1 cm distance but is comparable at larger distances. The Model STM125I anisotropy constant is very similar to that of the model 6711, 6702, and MED363I A/M seeds.

Mesh:

Year:  2001        PMID: 11393471     DOI: 10.1118/1.1367280

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Radiobiological effect induced by different activities of (125)I seed brachytherapy in a hepatocellular carcinoma model.

Authors:  Qing-Hong Qin; Bai-Sha Huang; Qi-Xing Tan; Wei-Ping Yang; Bin Lian; Chang-Yuan Wei
Journal:  Int J Clin Exp Med       Date:  2014-12-15

2.  Verification of air-kerma strength of 125I seed for permanent prostate implants in Japan.

Authors:  Iori Sumida; Masahiko Koizumi; Yutaka Takahashi; Toshiyuki Ogata; Yuichi Akino; Fumiaki Isohashi; Koji Konishi; Yasuo Yoshioka; Takehiro Inoue
Journal:  Int J Clin Oncol       Date:  2009-12-05       Impact factor: 3.402

Review 3.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

4.  A comparison of the dose distributions between the brachytherapy 125I source models, STM1251 and Oncoseed 6711, in a geometry lacking radiation equilibrium scatter conditions.

Authors:  Kenichi Tanaka; Ken-ichi Kamo; Kunihiko Tateoka; Osamu Asanuma; Kaori Sato; Hiromitsu Takeda; Koh-ichi Sakata; Jun Takada
Journal:  J Radiat Res       Date:  2015-01-24       Impact factor: 2.724

5.  Dosimetric parameters of three new solid core I-125 brachytherapy sources.

Authors:  Timothy D Solberg; John J DeMarco; Geoffrey Hugo; Robert E Wallace
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Dosimetric characterization of GMS BT-125-1 125 I radioactive seed with Monte Carlo simulations and experimental measurement.

Authors:  Nan Zhao; Ruijie Yang; Li Ren; Yi Fan; Junli Li; Jianguo Zhang
Journal:  J Appl Clin Med Phys       Date:  2017-09-14       Impact factor: 2.102

7.  Measured transverse-axis dosimetric parameters of the model STM1251 125I interstitial source.

Authors:  Z Li; J F Williamson
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

  7 in total