Literature DB >> 11392585

Diagostic value of respiratory impedance measurements in elderly subjects.

J P Janssens1, M C Nguyen, F R Herrmann, J P Michel.   

Abstract

Obstructive lung disease (OLD) is highly prevalent in elderly subjects but markedly under-diagnosed. Indeed, only 40-50% of hospitalized elderly patients are able to adequately perform spirometric tests. This study aimed to evaluate, in an acute-care geriatric hospital, the diagnostic value of measuring airway impedance (Zrs) by the forced oscillation technique (FOT) for: (1) identifying OLD and (2) identifying responders vs. non-responders to bronchodilators. Sixty-seven patients (aged 82+/-8 years) underwent consecutive measurement of Zrs and forced expiratory volumes before and after bronchodilators. Zrs was measured by FOT at frequencies of 4-30 Hz. Correlations, ROC curves and logistic regression models were established to determine the sensitivity (Se) and specificity (Sp) of Zrs in identifying OLD. Significant correlations were found between spirometric and Zrs measurements. The Zrs parameters yielding the best Se and Sp for detecting OLD were: Fn (resonant frequency; Se: 76%; Sp: 78%) and R0 (resistance extrapolated for a frequency of 0: Se: 76%; Sp: 74%). Using the logistic regression models, 76% of the patients were correctly classified as having OLD or not. Zrs was however not contributive in identifying responders to bronchodilators. Zrs measurements by FOT are contributive to the diagnosis of OLD in elderly hospitalized patients.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11392585     DOI: 10.1053/rmed.2001.1062

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  6 in total

1.  Accuracy of forced oscillation technique to assess lung function in geriatric COPD population.

Authors:  Hoi Nam Tse; Cee Zhung Steven Tseng; King Ying Wong; Kwok Sang Yee; Lai Yun Ng
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-05-26

2.  Impulse oscillometry system as an alternative diagnostic method for chronic obstructive pulmonary disease.

Authors:  Xia Wei; Zhihong Shi; Yajuan Cui; Jiuyun Mi; Zhengquan Ma; Jingting Ren; Jie Li; Shudi Xu; Youmin Guo
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.889

3.  Do impulse oscillometry parameters differ between children and adolescents with symptoms of rhinitis and those without?

Authors:  Juliana Cardoso; Bianca Kons Dos Santos; Luana Vincensi Dorigo; Renata Maba Gonçalves Wamosy; Bianca Dana Horongozo Itaborahy; Camila Isabel Santos Schivinski
Journal:  J Bras Pneumol       Date:  2022-07-15       Impact factor: 2.800

4.  Influence of the ageing process on the resistive and reactive properties of the respiratory system.

Authors:  Caio Vinicius Villalón e Tramont; Alvaro Camilo Dias Faria; Agnaldo José Lopes; José Manoel Jansen; Pedro Lopes de Melo
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

5.  On the respiratory mechanics measured by forced oscillation technique in patients with systemic sclerosis.

Authors:  Ingrid Almeida Miranda; Alvaro Camilo Dias Faria; Agnaldo José Lopes; José Manoel Jansen; Pedro Lopes de Melo
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

6.  Comparison of oscillometry devices using active mechanical test loads.

Authors:  Ronald J Dandurand; Jean-Pierre Lavoie; Larry C Lands; Zoltán Hantos
Journal:  ERJ Open Res       Date:  2019-12-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.