Literature DB >> 11390212

Investigation of highly sensitive piezoelectric immunosensors for 2,4-dichlorophenoxyacetic acid.

J Halámek1, M Hepel, P Skládal.   

Abstract

The improved highly sensitive piezoelectric immunosensor has been developed and evaluated using a model interaction of antibody with the model hapten-herbicide 2,4-dichlorophenoxyacetic acid (2,4-D). For immobilization of 2,4-D, the self-assembled layers of cystamine, 4-aminothiophenol or 3,3'-dithio-bis(propionic acid N-hydroxysuccinimide ester) were formed on smooth and rough crystals coated with gold or silver electrodes. The immunochemical interactions performed well in all cases, the aminothiophenol on gold was chosen as the optimum with regard to regeneration of immunosensing surfaces. The kinetics of interaction of surface-bound 2,4-D with free antibody provided significantly higher kinetic parameters (kinetic association rate constant) when using optically smooth crystals compared to common rough crystal. Therefore, the smooth crystal should be preferred for future kinetic studies. The competitive assay of the herbicide 2,4-D achieved a limit of detection of 10 ng/l using the monoclonal anti-2,4-D antibody F6C10. Finally, a direct assay format has been evaluated using a thicker layer of glutaraldehyde-crosslinked antibody on the sensing surface. The direct binding of a small herbicide molecule was followed in real time. The detected concentration of 2,4-D (5 microg/l) was low enough for future direct monitoring of this herbicide in water.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11390212     DOI: 10.1016/s0956-5663(01)00132-4

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures.

Authors:  Richard C Barry; Yuehe Lin; Jun Wang; Guodong Liu; Charles A Timchalk
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-11-19       Impact factor: 5.563

2.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

3.  Multifunctional Polypeptide EQCN Sensors: Probing the Cysteamine-Glutathione Film Permeability with Hg(II) Ions.

Authors:  Maria Hepel; Julia Dallas
Journal:  Sensors (Basel)       Date:  2008-11-14       Impact factor: 3.576

4.  A phage display screening derived Peptide with affinity for the adeninyl moiety.

Authors:  Louise Elmlund; Pernilla Söderberg; Subramanian Suriyanarayanan; Ian A Nicholls
Journal:  Biosensors (Basel)       Date:  2014-04-29

5.  Hierarchical thin film architectures for enhanced sensor performance: liquid crystal-mediated electrochemical synthesis of nanostructured imprinted polymer films for the selective recognition of bupivacaine.

Authors:  Subramanian Suriyanarayanan; Hazrat Nawaz; Natacha Ndizeye; Ian A Nicholls
Journal:  Biosensors (Basel)       Date:  2014-04-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.