Mechanical testing of a single rod versus a double rod in a long-segment animal model.

J M Wattenbarger1, J A Herring, D Bronson, R B Ashman.   

Abstract

This study involved the mechanical testing of single-rod segmental hook fixation and double-rod segmental hook fixation in a long-segment animal model. The goals were first to compare the flexibility of a single-rod scoliosis construct with that of a double-rod construct when tested in torsion, and second, to determine the effect of not using instrumentation with every vertebral segment for the single rod. Another study found that the single-rod construct was as stiff in torsion as the standard double-rod construct in a model of 10 vertebral segments. The amount of neutral zone (NZ) rotation was tested in five calf spines using an MTS (Material Testing System) machine. Five constructs were tested and included 1) a single rod with hooks at every level except the apex; 2) a single rod with two fewer hooks; 3) a single rod with four fewer hooks; 4) a double-rod construct; and 5) no instrumentation. The amount of NZ rotation between vertebral segments was measured over 12, 10, 8, 6, 4, and 2 vertebral segments. An analysis of variance with all constructs showed that the instrumented spines had significantly less movement than did the uninstrumented spine. Statistical comparison using analysis of variance of constructs (constructs 1 to 4) showed that over 12 vertebral segments (T4-L3), all single-rod constructs (constructs 1 to 3) allowed more NZ rotation than did the standard double-rod construct. This testing indicated that over 12 vertebral segments the single rod allowed more NZ rotation than a double-rod construct.

Entities:  

Mesh:

Year:  2001        PMID: 11389374     DOI: 10.1097/00002517-200106000-00008

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  3 in total

1.  Biomechanical study of anterior spinal instrumentation configurations.

Authors:  Luc P Cloutier; Carl-Eric Aubin; Guy Grimard
Journal:  Eur Spine J       Date:  2007-01-05       Impact factor: 3.134

2.  Range of motion after thoracolumbar corpectomy: evaluation of analogous constructs with a novel low-profile anterior dual-rod system and a traditional dual-rod system.

Authors:  Martin Gehrchen; Sajan K Hegde; Mark Moldavsky; Suresh Chinthukunta; Manasa Gudipally; Brandon Bucklen; Kanaan Salloum; Saif Khalil
Journal:  Eur Spine J       Date:  2015-04-28       Impact factor: 3.134

3.  Single rod instrumentation in patients with scoliosis and co-morbidities: Indications and outcomes.

Authors:  Athanasios I Tsirikos; Peter R Loughenbury
Journal:  World J Orthop       Date:  2018-09-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.