Initial stability of modular acetabular components. Comparative in-vitro study with polyethylene and ceramic liners.

R P Pitto1, G Willmann, M Schramm.   

Abstract

Modular acetabular components with alumina ceramic liners are currently used in total hip arthroplasty, but concerns have emerged regarding their high stiffness, which could cause impairment of stability, stress-shielding phenomena, and loosening. The purpose of the present biomechanical investigation was to compare the in-vitro initial stability of a modular press-fit acetabular component using a polyethylene liner and using an alumina liner. The initial stability was investigated by measuring the micromotion between the implant and the acetabulum during the application of physiological load (2.39 kN). The micromotion of the acetabular component was investigated in 10 acetabuli using a polyethylene liner and in 10 acetabuli using an alumina liner. Micromotion was assessed at the level of the Os ilium, Os pubis, and Os ischium using 3 electromagnetic transducers. The transducers have a sensitivity of 1 micron and a range of measurement of 500 microns. All implants have been fixed on human pelves made of polyurethane. Measurement of implant micromotion showed stable conditions at the level of the three main sectors of the acetabulum during all tests. No statistically significant differences of results were observed between the group of specimens with polyethylene liner and the group of specimens with alumina liner. The mean micromotion values of the uncemented cups were similar to the mean micromotion values of 10 cemented cups investigated to achieve comparative data of stability. In conclusion, the modular acetabular components inserted using an alumina liner showed a satisfactory initial stability in-vitro. The results do not contrast with those achieved using the same cup inserted with a polyethylene liner.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11388038     DOI: 10.1515/bmte.2001.46.4.109

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  3 in total

1.  Uncemented acetabular components with polyethylene or alumina liners.

Authors:  Rainer Schmidt; Gerd Willmann; Rocco Paolo Pitto
Journal:  Int Orthop       Date:  2003-01-28       Impact factor: 3.075

2.  Peri-acetabular bone mineral densityin total hip replacement.

Authors:  L Gauthier; L Dinh; P E Beaulé
Journal:  Bone Joint Res       Date:  2013-08-02       Impact factor: 5.853

3.  Two Different Methods to Measure the Stability of Acetabular Implants: A Comparison Using Artificial Acetabular Models.

Authors:  Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  Sensors (Basel)       Date:  2020-01-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.