Literature DB >> 11386609

Comparison of diagnostic performance of cardiac troponin I on the IMMULITE system with other automated troponin I assays in minor myocardial damage.

G Hafner1, D Peetz, H Erbes, F Post, M Dahm, A A Peivandi, B Sucké, S Blankenberg, H J Rupprecht, W Prellwitz.   

Abstract

An analytical and clinical evaluation of cardiac troponin I (cTnI) on the IMMULITE system is presented. The assay results were compared with those of the Stratus II and the Dimension RxL-HM. A between-run imprecision CV < 20% was found at a cTnI concentration of 0.23 microg/L (functional limit of detection). On the basis of a reference study including 215 patients without ischemic heart disease (97.5th percentile: 0.294 microg/L) and 36 patients clinically classified as having stable angina pectoris (<0.22 microg/L) a preliminary cutoff level of 0.3 microg/L was defined. Assay linearity, sample stability, influence of sample material and method comparison studies were performed. In patients with Duchenne's disease, chronic hemodialysis treatment, pulmonary embolism, coronary artery bypass surgery and minimally cardiac surgery the cTnI results of the IMMULITE agreed better with the Dimension RxL-HM than with the Stratus II data. Of 142 samples from patients with unstable angina 67 samples were classified as cTnI positive with the IMMULITE, 76 with the Dimension RxL-HM, and 62 with the Stratus II. In conclusion, the new assay is sensitive for the determination of cTnI and easy to perform within 45 min.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11386609     DOI: 10.1080/003655101300133667

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  3 in total

1.  The reporting of cardiac troponin.

Authors:  Peter E Hickman; Gus Koerbin; Jill Tate
Journal:  Clin Biochem Rev       Date:  2003-11

2.  Absolute quantification of C-reactive protein in human plasma derived from patients with epithelial ovarian cancer utilizing protein cleavage isotope dilution mass spectrometry.

Authors:  D Keith Williams; David C Muddiman
Journal:  J Proteome Res       Date:  2009-02       Impact factor: 4.466

3.  Diagnostic accuracy of heart fatty acid binding protein (H-FABP) and glycogen phosphorylase isoenzyme BB (GPBB) in diagnosis of acute myocardial infarction in patients with acute coronary syndrome.

Authors:  Zlatko Cubranic; Zeljko Madzar; Sanja Matijevic; Stefica Dvornik; Elizabeta Fisic; Vjekoslav Tomulic; Juraj Kunisek; Gordana Laskarin; Igor Kardum; Luka Zaputovic
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.