Literature DB >> 11384063

Derivation of electron and photon energy spectra from electron beam central axis depth dose curves.

J Deng1, S B Jiang, T Pawlicki, J Li, C M Ma.   

Abstract

A method for deriving the electron and photon energy spectra from electron beam central axis percentage depth dose (PDD) curves has been investigated. The PDD curves of 6, 12 and 20 MeV electron beams obtained from the Monte Carlo full phase space simulations of the Varian linear accelerator treatment head have been used to test the method. We have employed a 'random creep' algorithm to determine the energy spectra of electrons and photons in a clinical electron beam. The fitted electron and photon energy spectra have been compared with the corresponding spectra obtained from the Monte Carlo full phase space simulations. Our fitted energy spectra are in good agreement with the Monte Carlo simulated spectra in terms of peak location, peak width, amplitude and smoothness of the spectrum. In addition, the derived depth dose curves of head-generated photons agree well in both shape and amplitude with those calculated using the full phase space data. The central axis depth dose curves and dose profiles at various depths have been compared using an automated electron beam commissioning procedure. The comparison has demonstrated that our method is capable of deriving the energy spectra for the Varian accelerator electron beams investigated. We have implemented this method in the electron beam commissioning procedure for Monte Carlo electron beam dose calculations.

Entities:  

Mesh:

Year:  2001        PMID: 11384063     DOI: 10.1088/0031-9155/46/5/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  The effect of energy spectrum change on DNA damage in and out of field in 10-MV clinical photon beams.

Authors:  A O Ezzati; Y Xiao; M Sohrabpour; M T Studenski
Journal:  Med Biol Eng Comput       Date:  2014-10-29       Impact factor: 2.602

2.  Development of a Monte Carlo multiple source model for inclusion in a dose calculation auditing tool.

Authors:  Austin M Faught; Scott E Davidson; Jonas Fontenot; Stephen F Kry; Carol Etzel; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2017-08-01       Impact factor: 4.071

3.  Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.

Authors:  Jean-Emmanuel Bibault; Xavier Mirabel; Thomas Lacornerie; Emmanuelle Tresch; Nick Reynaert; Eric Lartigau
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

4.  A virtual source model for Monte Carlo simulation of helical tomotherapy.

Authors:  Jiankui Yuan; Yi Rong; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

  4 in total