Literature DB >> 11384062

A multiple source model for 6 MV photon beam dose calculations using Monte Carlo.

M K Fix1, M Stampanoni, P Manser, E J Born, R Mini, P Rüegsegger.   

Abstract

A multiple source model (MSM) for the 6 MV beam of a Varian Clinac 2300 C/D was developed by simulating radiation transport through the accelerator head for a set of square fields using the GEANT Monte Carlo (MC) code. The corresponding phase space (PS) data enabled the characterization of 12 sources representing the main components of the beam defining system. By parametrizing the source characteristics and by evaluating the dependence of the parameters on field size, it was possible to extend the validity of the model to arbitrary rectangular fields which include the central 3 x 3 cm2 field without additional precalculated PS data. Finally, a sampling procedure was developed in order to reproduce the PS data. To validate the MSM, the fluence, energy fluence and mean energy distributions determined from the original and the reproduced PS data were compared and showed very good agreement. In addition, the MC calculated primary energy spectrum was verified by an energy spectrum derived from transmission measurements. Comparisons of MC calculated depth dose curves and profiles, using original and PS data reproduced by the MSM, agree within 1% and 1 mm. Deviations from measured dose distributions are within 1.5% and 1 mm. However, the real beam leads to some larger deviations outside the geometrical beam area for large fields. Calculated output factors in 10 cm water depth agree within 1.5% with experimentally determined data. In conclusion, the MSM produces accurate PS data for MC photon dose calculations for the rectangular fields specified.

Entities:  

Mesh:

Year:  2001        PMID: 11384062     DOI: 10.1088/0031-9155/46/5/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Multiple-source models for electron beams of a medical linear accelerator using BEAMDP computer code.

Authors:  Nasrollah Jabbari; Amir Hoshang Barati; Leili Rahmatnezhad
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-30

2.  A single-source photon source model of a linear accelerator for Monte Carlo dose calculation.

Authors:  Obioma Nwankwo; Gerhard Glatting; Frederik Wenz; Jens Fleckenstein
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

3.  Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator.

Authors:  Subhalaxmi Mishra; P K Dixit; T Palani Selvam; Sanket S Yavalkar; D D Deshpande
Journal:  J Med Phys       Date:  2018 Jan-Mar

4.  Development of a virtual source model for Monte Carlo-based independent dose calculation for varian linac.

Authors:  James R Castle; Jingwei Duan; Xue Feng; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2022-02-09       Impact factor: 2.243

5.  A phase space model of a Versa HD linear accelerator for application to Monte Carlo dose calculation in a real-time adaptive workflow.

Authors:  James L Bedford; Rahul Nilawar; Simeon Nill; Uwe Oelfke
Journal:  J Appl Clin Med Phys       Date:  2022-06-14       Impact factor: 2.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.