Literature DB >> 11383807

Efficacy of a new coating material, PMEA, for cardiopulmonary bypass circuits in a porcine model.

H Suhara1, Y Sawa, M Nishimura, H Oshiyama, K Yokoyama, N Saito, H Matsuda.   

Abstract

BACKGROUND: A new coating material, poly-2-methoxyethyl acrylate (PMEA), was developed to improve the biocompatibility of cardiopulmonary bypass (CPB) circuits.
METHODS: To investigate the efficacy of the PMEA coating for CPB circuits, we compared PMEA-coated circuits (group P, n = 6) with uncoated circuits (group C, n = 6) and heparin (covalent-bonded heparin, Hepaface)-coated circuits (group H, n = 6) in a porcine CPB model.
RESULTS: Platelet counts were significantly preserved in groups P and H compared with those in group C (P versus C, p < 0.05). The plasma levels of thrombin-antithrombin complex and bradykinin were significantly lower at 120 minutes in groups P and H than in group C (thrombin-antithrombin: P versus C, p < 0.05; bradykinin: P versus C, p < 0.05). The amount of fibrinogen adsorbed onto the hollow fibers was markedly less in group P than in groups C and H.
CONCLUSIONS: The PMEA coating was equal to heparin coating in preventing reactions induced by CPB circuits, and might be superior to heparin coating in suppressing the adsorption of plasma proteins such as fibrinogen. Thus, PMEA coating may be a suitable means for improving the biocompatibility of CPB circuits.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11383807     DOI: 10.1016/s0003-4975(01)02466-3

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  18 in total

1.  In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.

Authors:  Angela Ask; David Holt; Lynette Smith
Journal:  J Extra Corpor Technol       Date:  2006-03

2.  Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.

Authors:  Joseph Deptula; Kimberly Glogowski; Kellie Merrigan; Kim Hanson; Donald Felix; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2006-03

3.  Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery.

Authors:  Katsuhiro Hosoyama; Koki Ito; Shunsuke Kawamoto; Kiichiro Kumagai; Masatoshi Akiyama; Osamu Adachi; Satoshi Kawatsu; Konosuke Sasaki; Marina Suzuki; Yumi Sugawara; Yuya Shimizu; Yoshikatsu Saiki
Journal:  J Artif Organs       Date:  2016-02-24       Impact factor: 1.731

Review 4.  Lung inflammatory response syndrome after cardiac-operations and treatment of lornoxicam.

Authors:  Kosmas Tsakiridis; Andreas Mpakas; George Kesisis; Stamatis Arikas; Michael Argyriou; Stavros Siminelakis; Paul Zarogoulidis; Nikolaos Katsikogiannis; Ioanna Kougioumtzi; Theodora Tsiouda; Eirini Sarika; Ioanna Katamoutou; Konstantinos Zarogoulidis
Journal:  J Thorac Dis       Date:  2014-03       Impact factor: 2.895

5.  In vivo evaluation of a new surfactant polymer coating mimicking the glycocalyx of endothelial cells.

Authors:  Akira Shiose; Tohru Takaseya; Hyun-Il Kim; Mariko Kobayashi; Tetsuya Horai; Santosh Rao; Yoko Arakawa; Masako Fujiki; Mark A McCarthy; Yubiao Liu; Jan J Lewandowski; Amy Davis; Kiyotaka Fukamachi
Journal:  ASAIO J       Date:  2011 Sep-Oct       Impact factor: 2.872

6.  Clinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting.

Authors:  See N Vang; Chad P Brady; Kevin A Christensen; Jack R Isler; Keith R Allen
Journal:  J Extra Corpor Technol       Date:  2005-03

7.  The adherence of platelets to adsorbed albumin by receptor-mediated recognition of binding sites exposed by adsorption-induced unfolding.

Authors:  Balakrishnan Sivaraman; Robert A Latour
Journal:  Biomaterials       Date:  2009-10-27       Impact factor: 12.479

8.  The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogen.

Authors:  Balakrishnan Sivaraman; Robert A Latour
Journal:  Biomaterials       Date:  2009-10-21       Impact factor: 12.479

9.  Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery.

Authors:  Yasuyuki Suzuki; Kazuyuki Daitoku; Masahito Minakawa; Kozo Fukui; Ikuo Fukuda
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

Review 10.  Strategies to prevent intraoperative lung injury during cardiopulmonary bypass.

Authors:  Efstratios E Apostolakis; Efstratios N Koletsis; Nikolaos G Baikoussis; Stavros N Siminelakis; Georgios S Papadopoulos
Journal:  J Cardiothorac Surg       Date:  2010-01-11       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.