Literature DB >> 11383789

Hemodynamics and gas exchange during carbon dioxide insufflation for totally endoscopic coronary artery bypass grafting.

C Byhahn1, S Mierdl, D Meininger, G Wimmer-Greinecker, G Matheis, K Westphal.   

Abstract

BACKGROUND: In addition to single-lung ventilation (SLV), positive-pressure CO2 insufflation is mandatory for totally endoscopic coronary artery bypass grafting. Studies on the effects of unilateral CO2 insufflation on hemodynamics produced controversial results, and bilateral insufflation has not been studied to our knowledge. The present study sought to investigate hemodynamics and gas exchange during unilateral and bilateral CO2 insufflation in patients who underwent totally endoscopic coronary artery bypass grafting.
METHODS: Eleven hemodynamic and gas exchange variables were monitored during 22 totally endoscopic coronary artery bypass grafting procedures with unilateral (n = 17) or bilateral (n = 5) CO2 insufflation at a pressure of 10 to 12 mm Hg. Data were obtained at baseline with double-lung ventilation, after institution of SLV, during insufflation, after cardiopulmonary bypass during SLV, and after return to double-lung ventilation.
RESULTS: Arterial oxygen tension decreased significantly during SLV, whereas the peak inspiratory pressure increased. In addition, central venous pressure and heart rate increased significantly during insufflation, but mean arterial pressure remained unchanged. Although the end-tidal CO2 pressure did not change, arterial carbon dioxide tension increased progressively to a maximum of 44.6 +/- 5.9 mm Hg during unilateral insufflation, and 55.7 +/- 14.6 mm Hg during bilateral insufflation (p < 0.05 versus baseline and between groups). Mixed venous oxygen saturation declined during SLV regardless of CO2 insufflation and recovered to baseline once double-lung ventilation was restarted. Left and right ventricular ejection fractions remained unaltered. No patient required inotropic or vasopressor support.
CONCLUSIONS: Carbon dioxide insufflation for totally endoscopic coronary artery bypass grafting with SLV had no adverse effects on hemodynamics. In contrast to a moderate increase of arterial carbon dioxide tension during unilateral insufflation, markedly elevated arterial carbon dioxide tension levels remain a cause of concern during bilateral insufflation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11383789     DOI: 10.1016/s0003-4975(01)02428-6

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  12 in total

1.  Efficacy and hemodynamic response of pleural carbon dioxide insufflation during thoracoscopic surgery in a swine vessel injury model.

Authors:  Ryo Okamura; Yusuke Takahashi; Hitoshi Dejima; Takashi Nakayama; Hirofumi Uehara; Noriyuki Matsutani; Masafumi Kawamura
Journal:  Surg Today       Date:  2016-03-17       Impact factor: 2.549

2.  Hybrid myocardial revascularization.

Authors:  Yugal Kishore Mishra; Jatin Yadav
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-03-05

3.  Robotically assisted atraumatic coronary artery bypass: a feasible option for off-pump coronary surgery.

Authors:  Espeed Khoshbin; Shirley Martin; Rodney Foale; Ara Darzi; Roberto Casula
Journal:  J Robot Surg       Date:  2010-06-13

Review 4.  [Coronary artery bypass grafting in conscious patients: a procedure with a perspective?].

Authors:  C Byhahn; D Meininger; P Kessler
Journal:  Anaesthesist       Date:  2008-12       Impact factor: 1.041

5.  Clinical outcomes of CO2-less single-port video-assisted thoracoscopic thymectomy versus open thymectomy: comparative study.

Authors:  Javier Aragón; Itzell Pérez Méndez; Alexia Gutiérrez Pérez
Journal:  J Vis Surg       Date:  2016-03-30

6.  Impact of artificial capnothorax on coagulation in patients during video-assisted thoracoscopic esophagectomy for squamous cell carcinoma.

Authors:  Qing-Xiang Mao; Wei Guo; Bing-Qiang Huang; Hong Yan
Journal:  Surg Endosc       Date:  2015-11-12       Impact factor: 4.584

7.  Arterial pCO2 changes during thoracoscopic surgery with CO2 insufflation and one lung ventilation.

Authors:  D T T Tran; N H Badner; G Nicolaou; W Sischek
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2010

8.  Asystole following positive pressure insufflation of right pleural cavity: a case report.

Authors:  Kari M Forde-Thielen; Mojca R Konia
Journal:  J Med Case Rep       Date:  2011-06-30

Review 9.  Anesthetic issues for robotic cardiac surgery.

Authors:  Wendy K Bernstein; Andrew Walker
Journal:  Ann Card Anaesth       Date:  2015 Jan-Mar

Review 10.  Anesthetic challenges in minimally invasive cardiac surgery: Are we moving in a right direction?

Authors:  Vishwas Malik; Ajay Kumar Jha; Poonam Malhotra Kapoor
Journal:  Ann Card Anaesth       Date:  2016 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.