Literature DB >> 11382934

Accuracy and precision of flowing afterglow mass spectrometry for the determination of the deuterium abundance in the headspace of aqueous liquids and exhaled breath water.

P Spanel1, D Smith.   

Abstract

We have assessed the accuracy and precision of our flowing afterglow mass spectrometric method (FA-MS) for absolute measurements of deuterium abundance in water using standardised tap water/D(2)O mixtures within the D/H range from 155 ppm (local tap water) to 1104 ppm, prepared by the gravimetric method. The results of this study show that a precision and accuracy of 1% can be achieved for the deuterium abundance in water samples. This is quite adequate for the main application, which is the rapid, non-invasive measurement of total body water by deuterium analysis of breath water vapour using the D(2)O dilution method. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11382934     DOI: 10.1002/rcm.310

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  Plasma volume, albumin, and fluid status in peritoneal dialysis patients.

Authors:  Biju John; B Kay Tan; Stephen Dainty; Patrik Spanel; David Smith; Simon J Davies
Journal:  Clin J Am Soc Nephrol       Date:  2010-06-10       Impact factor: 8.237

2.  Comparative measurements of total body water in healthy volunteers by online breath deuterium measurement and other near-subject methods.

Authors:  David Smith; Barbara Engel; Ann M Diskin; Patrik Spanel; Simon J Davies
Journal:  Am J Clin Nutr       Date:  2002-12       Impact factor: 7.045

3.  Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods.

Authors:  Barbara Engel; Patrik Spanel; David Smith; Ann Diskin; Simon J Davies
Journal:  Int J Body Compos Res       Date:  2004

4.  Determination of the deuterium abundances in water from 156 to 10,000 ppm by SIFT-MS.

Authors:  Patrik Španěl; Violetta Shestivska; Thomas W E Chippendale; David Smith
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-21       Impact factor: 3.109

5.  Measuring transport of water across the peritoneal membrane.

Authors:  Ramzana B Asghar; Ann M Diskin; Patrik Spanel; David Smith; Simon J Davies
Journal:  Kidney Int       Date:  2003-11       Impact factor: 10.612

6.  Combining near-subject absolute and relative measures of longitudinal hydration in hemodialysis.

Authors:  Cian Chan; Christopher McIntyre; David Smith; Patrik Spanel; Simon J Davies
Journal:  Clin J Am Soc Nephrol       Date:  2009-09-24       Impact factor: 8.237

7.  A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients.

Authors:  Cian Chan; David Smith; Patrik Spanel; Christopher W McIntyre; Simon J Davies
Journal:  Nephrol Dial Transplant       Date:  2008-03-08       Impact factor: 5.992

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.