In vitro comparison of the two hard-hard articulations for total hip replacements.

C Rieker1, R Konrad, R Schön.   

Abstract

Polyethylene particle disease is one of the major causes of late aseptic loosening of total hip replacement. Two hard-hard articulations (alumina-on-alumina and metal-on-metal) have been developed in Europe as an alternative to the ultra-high molecular weight polyethylene (UHMWPE) articulations. Even though these hard-hard articulations are on the market and numerous reports have been published about them, only a very limited number of studies allowing a direct in vitro comparison of the two articulations have been published so far. This paper compares in vitro these two types of articulation (alumina-on-alumina and metal-on-metal), which have been tested with a hip simulator for their tribological behaviour using exactly the same experimental methodology. This comparison shows that these two types of hard-hard articulation have very similar abrasive wear behaviour with four main features: 1. A running-in wear period (1 x 10(6) cycles) gives a cumulative wear of about 20 microns with head diameters of 28 mm. 2. After the running-in wear, there is a stabilization of the linear wear behaviour with a low linear wear rate/10(6) cycles for both types of articulation. 3. The volumetric wear rate of both articulations (< 2.0 mm3/year for head diameters of 28 mm) is significantly lower than that observed for metal-on-polyethylene or ceramic-on-polyethylene articulations having the same head diameter. 4. Abrasive wear is readily apparent (indicating a mixed lubrication regime) with both types of articulation. The extremely low wear performance of these articulations is confirmed and they constitute a low-wear alternative to the UHMWPE articulations currently used.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11382074     DOI: 10.1243/0954411011533715

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  3 in total

Review 1.  Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-10-05       Impact factor: 2.045

2.  Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator.

Authors:  Parshia Moghadas; Aziza Mahomed; Duncan E T Shepherd; David W L Hukins
Journal:  Proc Inst Mech Eng H       Date:  2015-03       Impact factor: 1.617

3.  Retrieval analysis of alumina ceramic-on-ceramic bearing couples.

Authors:  Muhammad Korim; Susan Scholes; Anthony Unsworth; Richard Power
Journal:  Acta Orthop       Date:  2014-04       Impact factor: 3.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.