Literature DB >> 11382072

Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement.

A Wang1, A Essner, R Klein.   

Abstract

This paper studies the effect of contact stress on friction and wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups by means of friction and wear joint simulator testing under serum lubrication. For a given applied load, increasing the contact stress by increasing the ball/socket radial clearance decreased both the coefficient of friction and the wear rate. Friction and wear were highly correlated. The dependence of friction on contact stress for the UHMWPE socket under serum lubrication was similar to that of semi-crystalline polymers under dry sliding. This finding indicates the occurrence of partial dry contact at asperity levels for the metal-polyethylene ball-in-socket joint under serum lubrication.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11382072     DOI: 10.1243/0954411011533698

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  11 in total

1.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

2.  2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total knees.

Authors:  John Fisher; Louise M Jennings; Alison L Galvin; Zhongmin M Jin; Martin H Stone; Eileen Ingham
Journal:  Clin Orthop Relat Res       Date:  2009-08-11       Impact factor: 4.176

3.  Quantification of clearance and creep in acetabular wear measurements.

Authors:  Mo Saffarini; Thomas Gregory; Eric Vandenbussche
Journal:  Ann Transl Med       Date:  2016-04

Review 4.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

5.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

6.  Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study.

Authors:  Stefan Schroeder; Mareike Schonhoff; Maximilian Uhler; Steffen Braun; Sebastian Jaeger; Tobias Renkawitz; Jan Philippe Kretzer
Journal:  Clin Orthop Relat Res       Date:  2022-05-17       Impact factor: 4.755

7.  Wear behavior of an unstable knee: stabilization via implant design?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  Biomed Res Int       Date:  2014-09-09       Impact factor: 3.411

8.  Rapid prototyping for in vitro knee rig investigations of prosthetized knee biomechanics: comparison with cobalt-chromium alloy implant material.

Authors:  Christian Schröder; Arnd Steinbrück; Tatjana Müller; Matthias Woiczinski; Yan Chevalier; Patrick Weber; Peter E Müller; Volkmar Jansson
Journal:  Biomed Res Int       Date:  2015-03-24       Impact factor: 3.411

9.  Range of Movement for Impingement and Dislocation Avoidance in Total Hip Replacement Predicted by Finite Element Model.

Authors:  Laura Ezquerra; María Paz Quilez; María Ángeles Pérez; Jorge Albareda; Belén Seral
Journal:  J Med Biol Eng       Date:  2017-01-21       Impact factor: 1.553

10.  In vivo measured joint friction in hip implants during walking after a short rest.

Authors:  Philipp Damm; Alwina Bender; Georg Duda; Georg Bergmann
Journal:  PLoS One       Date:  2017-03-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.